Ion Selective Electrodes (ISE)

Thermo Scientific™ Orion™ Fluoroborate Half-cell

Thermo Scientific™

Orion™ Fluoroborate Half-cell



 
  • Calibration Standards catalog number: Consult instruction manual
  • Required ISA catalog number: 930711
  • Required Reference : 900200

Thermo Scientific™ Orion™ Thiocyanate Half-Cell Electrode

Thermo Scientific™

Orion™ Thiocyanate Half-Cell Electrode



Perform quick, accurate and economical measurement of thiocyanate ions in aqueous solutions in the range 5 × 10-6M to 1M with the Thermo Scientific™ Orion™ Thiocyanate Half-cell.

Includes:

  • 1m cables for U.S. standard and BNC electrodes
 

THERMO SCIENTIFIC™ Orion™ Surfactant Half-Cell

THERMO SCIENTIFIC™ 

Orion™ Surfactant Half-Cell

Conduct end point detection in titrations of anionic or cationic surfactants in a solution with the Thermo Scientific™ Orion™ Surfactant Half-Cell. A potentiometric sensor, it is a surfactant-detecting electrode in anionic or cationic titration which is specifically designed for use on Orion 960 Autochemistry system.

Thermo Scientific™ Orion™ Carbon Dioxide Electrode

Thermo Scientific™

Orion™ Carbon Dioxide Electrode



Measure carbon dioxide, carbonate and bicarbonate in aqueous solutions quickly and accurately with the Thermo Scientific™ Orion™ 9502BNWP Carbon Dioxide Electrode.

Thermo Scientific™ Orion™ Chlorine Electrodes

 
Thermo Scientific™

Orion™ Chlorine Electrodes



Measure total residual chlorine quickly and accurately with the Thermo Scientific™ Orion™ Chlorine Electrodes. All forms of total residual chlorine are measured.
 

Thermo Scientific™ Orion™ Cupric Electrodes

Thermo Scientific™

Orion™ Cupric Electrodes



Measure cupric ions in aqueous solutions quickly, simply, accurately and economically with the Thermo Scientific™ Orion™ Cupric Electrodes. No separate reference electrode is needed with this electrode, making it convenient to use with small sample volumes.

No separate reference electrode is needed with this electrode, making it convenient to use with small sample volumes.
  • Calibration Standards Catalog number: 0.1 M Cu(NO3)2/942906
  • Required ISA Catalog number: 940011
 

Thermo Scientific™ Orion™ Cadmium Electrodes

Thermo Scientific™

Orion™ Cadmium Electrodes



Measure cadmium ions in aqueous solutions quickly, simply and economically with the Thermo Scientific™ Orion™ Cadmium Electrodes. A separate reference electrode is unnecessary with this electrode, making it convenient to use with small sample volumes.

Thermo Scientific™ Orion™ Bromide Electrodes

 
Thermo Scientific™

Orion™ Bromide Electrodes



Measure bromide ions in aqueous solutions quickly, simply and economically with the Thermo Scientific™ Orion™ Bromide Electrodes. A separate reference electrode is unnecessary with this electrode, making it convenient to use with small sample volumes.

 

Thermo Scientific™ Orion™ Silver/Sulfide Electrodes

Thermo Scientific™

Orion™ Silver/Sulfide Electrodes



Make quick, simple, accurate and economical measurements of silver and sulfide ions in aqueous solutions with Thermo Scientific™ Orion™ Silver/Sulfide Electrodes. These electrodes have dual electrode-measuring silver and sulfide ions in aqueous solutions, and perform low-level cyanide and halide titrations.

 

Thermo Scientific™ Orion™ Calcium Electrodes

Thermo Scientific™

Orion™ Calcium Electrodes



Measure calcium in aqueous solutions simply, accurately and economically with Thermo Scientific™ Orion™ Calcium Electrodes. No separate reference electrode is needed with this electrode, making it convenient to use with small sample volumes.

Thermo Scientific™ Orion™ Potassium Electrodes

Thermo Scientific™

Orion™ Potassium Electrodes



Measure potassium in aqueous solutions simply, accurately and economically with Thermo Scientific™ Orion™ Potassium Electrodes. A separate reference electrode is unnecessary with this electrode, making it convenient to use with small sample volumes.

Thermo Scientific™ Orion™ Iodide Electrodes

Thermo Scientific™

Orion™ Iodide Electrodes



Get fast and stable readings using Thermo Scientific™ Orion™ Iodide Electrodes with built-in Thermo Scientific™ Sure-Flow™ reference. Combination design decreases the amount of required sample and reduces waste.

  • Calibration standards catalog number: 945306 - 0.1M NaI Required ISA catalog number: 940011

Thermo Scientific™ Orion™ Cyanide Electrodes

Thermo Scientific™

Orion™ Cyanide Electrodes


 
Measure cyanide ions in aqueous solutions quickly, simply and economically with Thermo Scientific™ Orion™ Cyanide Electrodes. No separate reference electrode is needed with this electrode, making it convenient to use with small sample volumes.

Thermo Scientific™ Orion™ Sodium Electrodes

Thermo Scientific™

Orion™ Sodium Electrodes


 

Measure sodium in aqueous solutions quickly, accurately and economically with Thermo Scientific™ Orion™ Sodium Electrodes. A unique redox internal system with a Thermo Scientific™ Orion™ ROSS™ electrode provides faster response, and greater stability and accuracy than conventional sodium electrodes.
 

Includes:

  • Sodium BNC electrodes have 1m cables
  • ROSS sodium electrode filling solution: 50mL
  • Sodium ionic strength adjustor (ISA): 475mL
  • Sodium known addition standard: 475mL
  • 1000ppm sodium standard with ISA: 475mL
  • 1000ppm sodium standard: 475mL
  • Sodium reconditioning solution: 475mL
  • Sodium electrode storage solution: 475mL

Connector Types Waterproof BNC
Description ROSS sodium combination electrode
Filling Solution Type 900010 or 900012 for low level Na+; ROSS sodium electrode filling solution: 50 mL
Length (Metric) Cable 1M
Material Sodium
Operating Range (Metric) 1 x 10-6 M to saturated 0.02 ppm to saturated
For Use With (Equipment) ISE Meters
Temperature (Metric) Operating 0° to 100°C
Type Sodium Combination Ion Selective Electrode
Unit Size Each

Thermo Scientific™ Orion™ Chloride Electrode

Thermo Scientific™

Orion™ Chloride Electrodes


 

Measure free chloride in the range of 1 x 10-5M to 1M with Thermo Scientific™ Orion™ Chloride Electrodes
 

  • Calibration standards: 941706 (0.1M NaCl); 941707 (100ppm Cl); 941708 (1000ppm Cl)
  • Required ISA: 940011 or 941709/CISA

Connector Types Waterproof BNC
Description Ionplus Sure-Flow Solid State Combination
Item Description Model 9617BNWP; Orion Chloride Combin.
For Use With (Equipment) Chloride electrodes can be used on any ISE meter with a BNC connection The electrodes can also be used on meters with a variety of inputs when an adapter cable is used.
Type Combination Ion Selective Electrode
Unit Size Each

Thermo Scientific™ Orion™ Nitrate Electrodes

Thermo Scientific™

Orion™ Nitrate Electrodes


 
Measure nitrate in aqueous solutions simply, accurately and economically with Thermo Scientific™ Orion™ Nitrate Electrodes. A separate reference electrode is unnecessary with this electrode, making it convenient to use with small sample volumes.

  • Calibration standards catalog number: 920706 — 0.1M NaNO3; 920707 — 1000ppm N; 930707 — 100ppm N
  • Required ISA catalog number: 930711 or 930710/nitrate ISS
Connector Types BNC
Description Half-Cell Nitrate Electrode with Waterproof BNC Connector
Drift drift-free potentials
Junction Free-flowing Sure-Flow™ junction assures stable
For Use With (Equipment) ISE Meters
Type Combination Ion Selective Electrode
Unit Size Each

Thermo Scientific™ Orion™ High-Performance Ammonia Electrode

Thermo Scientific™

Orion™ High-Performance Ammonia Electrode

Obtain a more linear response at lower levels and improved response time in ammonia measurements with the Thermo Scientific™ Orion™ High-Performance Ammonia Electrode, an ammonia gas-sensing electrode.

Features:

  • Response time of 1 minute in sample concentrations of 1ppm and higher; fast results make it easy to combine functionality with autosamplers
  • Keying feature on the electrode body prevents membrane from twisting or breaking during assembly
  • Choice of preassembled outer body with membrane cap or loose membranes
  • New wastewater applications developed using known addition and direct measurement techniques
  • EPA-compliant method
Includes:
  • Waterproof BNC connector
  • 1m cable
  • 20 loose membranes (951214)
  • One preassembled outer body and membrane cap (951215)
  • Two 60mL bottles of electrode filling solution (951209)
  • Spout cap and tweezers
Connector Types BNC
Description Ammonia High Performance Ion Selective Electrode
Diameter (Metric) Body 12mm
Filling Solution Type High performance ammonia electrode filling solution
Internal Reference Volatile amines
Length (Metric) 120mm
Length (Metric) Cable 1M
Material Epoxy
Temperature (English) Operating 32° to 122°F
Item Description Connector: Waterproof BNC
Temperature (Metric) Operating 0° to 50°C
Type Ammonia Electrode
Unit Size Each

Thermo Scientific™ Orion™ Ammonia Gas Sensing ISE Electrodes

Thermo Scientific™

Orion™ Ammonia Gas Sensing ISE Electrodes


 

Get quick, reliable and accurate measurements of dissolved ammonia in aqueous solutions with the Thermo Scientific™ Orion™ Ammonia Gas Sensing ISE Electrode.
 

Connector Types Waterproof BNC
Description Ammonia Gas Sensing ISE Electrode
Length (English) 5.87 in.
Length (English) Cable 29.5 in.
Length (Metric) 15.1cm
Length (Metric) Cable 75cm
Material Epoxy
Operating Range (Metric) Ranges :1.0 to 5 x 10E7M
Temperature (English) Operating 32° to 122°F
Item Description Ammonia gas sensing combination
Temperature (Metric) Operating 0° to 50°C
Type Ammonia Gas-Sensing ISE Electrode
Unit Size Each

Thermo Scientific™ Orion™ Fluoride Electrodes

Thermo Scientific™

Orion™ Fluoride Electrodes

Measure free fluoride ions in aqueous solutions quickly, simply, accurately and economically with the Thermo Scientific™ Orion™ Fluoride Electrodes. The Thermo Scientific™ Sure-Flow™ junction allows easy cleaning and is easy to use in tough samples.The half-cell electrode requires a separate reference electrode. We recommend the reference electrode 900100 to be used with the half-cell electrodes 9409BN and 9409SC

The measurement of fluoride in drinking water using an ion selective electrode is an approved ASTM method: ASTM D 1179 A separate reference electrode is unnecessary with the combination fluoride electrode, making it convenient to use with small sample volumes.

  • Free-flowing Sure-Flow junction assures stable, drift-free potentials.
  • When conventional electrode junctions clog, the Sure-Flow junction can be opened and flushed clean simply by pressing the cap.
  • Fluoride Half-Cell Electrode used in conjunction with the Orion 900100 Single Junction Reference electrode offers the benefits of the Sure-Flow junction design:
    • Calibration standards catalog number: 940906 — 0.1 M NaF; 940907 — 100ppm F-; 040906 — 1ppm F- with TISAB II; 040907 — 2ppm F- with TISAB II; 940908 — 10 ppm F- with TISAB II
    • Required ISA catalog number: 940909 — TISAB II; 940911 — TISAB III

 