![]() SBS-200CT FORKLIFT BATTERY REGENERATOR & DISCHARGE CYCLERMotive Power Battery Discharge and Charge Cycle Testing with Individual Cell Monitoring Capabilities
The SBS-200CT is a discharge and charge cycler for battery testing and battery rejuvenation. The voltage range of 24–96 Vdc covers many types of traction batteries including: stationary, forklifts, automobile, golf cart, train, wheel chair, etc. When equipped with any industrial charger (compatible with most models, sold separately), the SBS-200CT provides an unmanned discharge and charge cycling solution to help increase battery capacity and prevent scrapping and warrantying those batteries. The unit includes wireless modules to collect and record individual cell readings during discharge/charge and software to generate detailed reports. Applications
Benefits
Features
Computer Analysis Software
Wireless Modules
SBS-200CT Includes
| ![]() SBS-4815CT BATTERY CAPACITY TESTERBattery Discharger / Capacity Tester for 20–60 Vdc Battery Systems The SBS-4815CT is a fully programmable and portable constant current load bank including individual cell monitoring wireless modules with detailed data acquisition, display and reporting capabilities. Built-in memory continuously records discharge data including: overall system voltage, current and individual cell voltages (when modules are installed). Parallel OperationAlone the SBS-4815CT has a 0–150 Amp constant current draw range. However it is possible to parallel additional load banks of the same voltage range with the SBS-4815CT to increase current draw.
With the optional P/N 8400-600A DC clamp the user can discharge up to 750 Amps and the SBS-4815CT will monitor the total DC current being drawn by up to three load banks in parallel. Benefits
Features
Analytical Software and Internal Memory
Wireless Modules
SBS-4815CT Includes
| ![]() SBS-1110S BATTERY CAPACITY TESTERConstant Current DC Load Bank 125 Vdc 0–100 Amp The only way to know if your stationary batteries will perform to specification is to test them regularly. NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five (5 )years and VRLA batteries every 12–18 months. The SBS-1110S constant current load banks are an easy and affordable way to perform accurate IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad) and IEEE1188 (VRLA) load tests. These units are quick and easy to set up. They display the voltage, current and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test. These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge. Built-in Protection
Features
3 adjustable stop points
| ![]() SBS-1230S BATTERY CAPACITY TESTERConstant Current DC Load Bank 125 Vdc 0–300 Amp The only way to know if your stationary batteries will perform to specification is to test them regularly. NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five (5 )years and VRLA batteries every 12–18 months. The SBS-1230S constant current load banks are an easy and affordable way to perform accurate IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad) and IEEE1188 (VRLA) load tests. These units are quick and easy to set up. They display the voltage, current and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test.
These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge. Built-in Protection
Features
3 adjustable stop points
|
![]() SBS-2206S BATTERY CAPACITY TESTERConstant Current DC Load Bank 250 Vdc 0–60 Amp The only way to know if your stationary batteries will perform to specification is to test them regularly. NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five (5 )years and VRLA batteries every 12–18 months. The SBS-2206S constant current load banks are an easy and affordable way to perform accurate IEEE450 (Vented Lead-Acid), IEEE1106 (Ni-Cad) and IEEE1188 (VRLA) load tests. These units are quick and easy to set up. They display the voltage, current and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test.
These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge. Built-in Protection
Features
3 adjustable stop points
| ![]() SBS-2415S BATTERY CAPACITY TESTERConstant Current DC Load Bank 250 Vdc 0–150 Amp The only way to know if your stationary batteries will perform to specification is to test them regularly. NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five (5 )years and VRLA batteries every 12–18 months. The SBS-2415S constant current load banks are an affordable way to perform easy and accurate IEEE450 (vented lead acid), IEEE1106 (NiCd) and IEEE1188 (VRLA) load tests. These units are quick and easy to set up. They display the voltage, current and Ah removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the test.
These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharg Built-in Protection
Features
3 adjustable stop points
| ![]() SBS-4830S BATTERY CAPACITY TESTERConstant Current DC Load Bank 20–40 Vdc 0–150 Amp / 40–60 Vdc 0–300 Amp The only true way to be certain if your stationary batteries will perform to specification under load is to capacity test the batteries regularly. NERC standard PRC-005-2 requires that vented lead acid and nickel cadmium (NiCd) systems be discharge tested every six (6) years and valve regulated lead acid (VRLA) batteries every three (3) years. IEEE recommends load testing stationary flooded/vented lead acid and NiCd stationary batteries every five (5) years and VRLA batteries every 12–18 months. The SBS-4830S constant current load bank is an affordable way to perform easy and accurate load tests, including IEEE450 (vented lead acid), IEEE1106 (NiCd) and IEEE1188 (VRLA) load tests. SBS load banks are quick and easy to set up. The SBS-4830S load bank includes a touch screen to set test parameters and display voltage, current and amp hours (Ah) removed from the string during the test. Since this is a constant current load bank, the user also does not have to adjust the current during the load test.
These load banks come standard with multiple adjustable stop points and built-in protection to ensure that the batteries are never damaged due to over-discharge. Built-in Protection
Features
3 adjustable stop points
| ![]() SBS-8400 BATTERY CAPACITY TESTERBattery Capacity Tester with Monitoring 10–300 Vdc, 0–120 Amp Constant Current Smart Load Bank with Individual Cell Monitoring Capabilities for NERC and IEEE load testing The SBS-8400 is a versatile and fully programmable, constant current discharge load bank with detailed data acquisition and display capabilities. The unit features a user-friendly touch screen menu and a complete built-in data monitoring/acquisition system when paired with wireless modules and software. Unlike basic load banks, the SBS-8400 is a high-tech solution for easy, efficient collection of data and generation of records for archiving. Paralleling Load BanksAlone, the SBS-8400 has a 0–120 Amp constant current draw range. However, it is possible to parallel additional compatible load banks with the SBS-8400 to increase the current.
With the optional P/N 8400-600A DC clamp the user can discharge up to 720 Amps and the SBS-8400 will monitor the total DC current being drawn by up to two (2) additional load banks in parallel. Applications
Benefits
Features
Computer Analysis Software
SBS-8400 Includes
|