LELab Sdn Bhd
18, Jalan Sungai Burung U32/U,
Seksyen 32, Bukit Rimau,
40460 Shah Alam,
Selangor Darul Ehsan, Malaysia.
+603-5525 3833
+603-5525 3832

AquaSensors AnalogPlus

AV88 AnalogPlus™ Universal Analyzer

Conveniently display sensor and temperature data with the Thermo Scientific™ AquaSensors™ AV88 AnalogPlus™ Universal Analyzer, which connects to any Thermo Scientific™AnalogPlus™ system via 1/4 DIN enclosure.

Description

Conveniently display sensor and temperature data with the Thermo Scientific™ AquaSensors™ AV88 AnalogPlus™ Universal Analyzer, which connects to any Thermo Scientific™AnalogPlus™ system via 1/4 DIN enclosure.

 
For Use With (Equipment) Thermo Scientific™ AnalogPlus™ system
Type Universal Analyzer
Description AV88 AnalogPlus Universal Analyzer
Max. Relative Humidity 95%, non-condensing
Outputs Two isolated 4 to 20mA outputs assigned to parameter; PID function with pH and Conductivity; Loop power provided by AV88
Power Supply Input 10 to 30VDC or 90 to 240VAC; (optional) Power: 2W at 25°C
Temperature (Metric) Operating -20° to +65°C
Item Description AV88
Sensor Connections Support pH, ORP, Two-electrode Conductivity and Resistivity, Toroidal Conductivity, Dissolved Oxygen, Ozone, and Turbidity measurementy; 1 in. long personality module plugs into the AV88 for use with any AnalogPlus sensor with a PT1000 temperature element
Certifications/Compliance Meets CE requirements for heavy industrial use
Unit Size -

AnalogPlus™ Differential pH Sensor 1.0 Inch

Conduct a wide array of demanding industrial applications with Thermo Scientific™ AquaSensors™ AnalogPlus™ Differential pH Sensors. Sensors are available in a choice of materials for a wide range of applications.

  • Replaceable salt bridge to extend sensor life
  • Offered with NTC300 or PT1000 temperature elements
  • Electrode protection options
 
For Use With (Equipment) AV88 Universal Analyzer
P99 pH/ORP Analyzer
Type Differential pH sensor
Accuracy 0.1% of reading
Description Differential pH sensor - 1.0 in.
Max. Flow Rate 10 ft./sec.
Max. Pressure 100psig (at 95°C); 85psig (at 75°C)
Step Response Time 90% in 30 seconds
Temperature (English) Operating 23° to 203°F PEEK Sensor Head; 23° to 167°F CPVC Sensor Head
Temperature (Metric) Operating -5° to +95°C (PEEK Sensor Head)/-5° to +75°C (CPVC Sensor Head)
Unit Size -

AnalogPlus™ Differential pH Sensor 1.5 Inch

Conduct a wide array of demanding industrial applications with Thermo Scientific™ AquaSensors™ AnalogPlus™ Differential pH Sensors. Sensors are available in a choice of materials for a wide range of applications.

  • Replaceable salt bridge to extend sensor life
  • Offered with NTC300 or PT1000 temperature elements
  • Electrode protection options
 
For Use With (Equipment) AV88 Universal Analyzer
P99 pH/ORP Analyzer
Type Differential pH sensor
Accuracy 0.1% of reading
Description Differential pH sensor - 1.5 in.
Max. Flow Rate 10 ft./sec.
Max. Pressure 100psig (at 95°C); 85psig (at 75°C)
Step Response Time 90% in 30 seconds
Temperature (English) Operating 23° to 203°F PEEK Sensor Head; 23° to 167°F CPVC Sensor Head
Temperature (Metric) Operating -5° to +95°C (PEEK Sensor Head)/-5° to +75°C (CPVC Sensor Head)
Unit Size -

AnalogPlus™ Differential ORP Sensor 1.0 Inch

Thermo Scientific AquaSensors AnalogPlus series for challenging process applications.

AquaSensors AnalogPlus ORP 1.0 Sensor

  • 1 inch NPT mounting
  • Differential ORP sensor designed for continuous use in the most demanding industrial applications
  • Replaceable salt bridge extends sensor life
  • Offered with NTC300 or PT 1000 temperature element
  • Electrode protection options
  • Available in choice of materials for a wide range of applications

Markets/Applications

  • Wastewater treatment
  • Metal finishing
  • Bleaching pulp
  • Disinfection control
 
For Use With (Equipment) AV88 Universal Analyzer
P99 pH/ORP Analyzer
Type Differential ORP sensor
Accuracy 0.1% of reading
Description Differential ORP sensor - 1.0 in.
Max. Flow Rate 10 ft./sec.
Max. Pressure 100psig (at 95°C); 85psig (at 75°C)
Step Response Time 90% in 30 seconds
Temperature (English) Operating 23° to 203°F PEEK Sensor Head; 23° to 167°F CPVC Sensor Head
Temperature (Metric) Operating -5° to +95°C (PEEK Sensor Head)/-5° to +75°C (CPVC Sensor Head)
Unit Size -

AnalogPlus™ Differential ORP Sensor 1.5 Inch

Thermo Scientific AquaSensors AnalogPlus series for challenging process applications.

AquaSensors AnalogPlus ORP 1.5 Sensor

  • 1.5 inch NPT mounting
  • Differential ORP sensor designed for continuous use in the most demanding industrial applications
  • Large reference chamber reduces calibration frequency
  • Replaceable salt bridge extends sensor life
  • Offered with NTC300 or PT 1000 temperature element
  • Electrode protection options
  • Available in choice of materials for a wide range of applications

Markets/Applications

  • Wastewater treatment
  • Metal finishing
  • Bleaching pulp
  • Disinfection control
 
For Use With (Equipment) AV88 Universal Analyzer
P99 pH/ORP Analyzer
Type Differential ORP sensor
Accuracy 0.1% of reading
Description Differential ORP sensor - 1.5 in.
Max. Flow Rate 10 ft./sec.
Max. Pressure 100psig (at 95°C); 85psig (at 75°C)
Step Response Time 90% in 30 seconds
Temperature (English) Operating 23° to 203°F PEEK Sensor Head; 23° to 167°F CPVC Sensor Head
Temperature (Metric) Operating -5° to +95°C (PEEK Sensor Head)/-5° to +75°C (CPVC Sensor Head)
Unit Size -

AnalogPlus™ Conductivity/Resistivity Sensors

Continuously use Thermo Scientific™ AquaSensors™ AnalogPlus™ Conductivity/Resistivity Sensors - 1″ in the most demanding industrial applications.

  • 0 to 5000μS/cm measurement range (1.0 cell)
  • 0 to 18.2 Mohm-cm measurement range (0.01 cell)
  • Titanium electrodes (0.01, 0.1 and 1.0 cell constants)
  • Offered in CPVC where higher cost materials are not required, or in Thermo Scientific™ PEEK™ for high temperature applications

Recommended for:

  • Food processing
  • Pharmaceutical
  • Water production
  • Reverse osmosis filters
  • Ultrafiltration
  • Distilled water
  • Semiconductor
  • Power generation
 
For Use With (Equipment) AV88 Universal Analyzer
Type CPVC or PEEK
Accuracy 0.1% of reading
Description Conductivity/Resistivity Sensors
Max. Flow Rate 10 ft./sec.
Max. Pressure 150psig (at 95°C); 150psig (at 75°C)
Range 0.01 cell: 18.2 to 50; 0.1 cell: 0 to 500; 1.0 cell: 0 to 5000Mohm-cm to mS/cm/; mS/cm; mS/cm
Resolution 4.5 significant digits
Step Response Time 90% in 30 seconds
Temperature (English) Operating 23° to 203°F PEEK Sensor Head; 23° to 167°F CPVC Sensor Head
Temperature (Metric) Operating -5° to +95°C (PEEK Sensor Head)/-5° to +75°C (CPVC Sensor Head)
Item Description Conductivity/Resistivity sensors
Unit Size -

AnalogPlus™ Conductivity/Resistivity Sensors ¨C Sanitary Style

AnalogPlus™ Conductivity/Resistivity Sensors ¨C High Temperature & Pressure Boiler , Condensate Design

AnalogPlus™ Conductivity/Resistivity Sensors ¨C Compression Fitting Style

AnalogPlus™ Toroidal Conductivity Sensors

Continuously use Thermo Scientific™ AquaSensors™ AnalogPlus™ Toroidal Conductivity Sensors in the most demanding industrial applications.

  • 0 to 2S/cm measurement range with 1μS/cm resolution
  • Offered in Thermo Scientific™ PEEK™ for high temperature/sanitary applications
  • Offered in CPVC for wide measurement range at the price of many two-electode sensors
  • For use with AV88 universal analyzer
Recommended for:
  • Chemical production
  • Metal finishing
  • Semiconductors
  • Pulp and paper
  • Food processing
  • Pharmaceuticals
 
For Use With (Equipment) AV88 Universal Analyzer
Type Toroidal Conductivity Sensors, CPVC or PEEK
Accuracy 0.1% of reading
Description Toroidal Conductivity Sensors
Max. Flow Rate 10 ft./sec.
Max. Pressure 200psig (at 100°C); 100psig (at 75°C)
Range 0 to 2,000,000µS/cm
Resolution 4.5 significant digits
Temperature (English) Operating 23° to 392°F PEEK Sensor Head/CPVC Sensor Head
Temperature (Metric) Operating -5° to +200°C
Unit Size -

AnalogPlus™ DO (ppm) Sensor

Repeatedly perform the most demanding industrial applications with the Thermo Scientific™ AquaSensors™ AnalogPlus™ DO (ppm) Sensor.

Features:
  • 0 to 40ppm measurement range
  • 0.01ppm resolution

Recommended for:

  • Municipal and industrial wastewater
  • Aquaculture
  • Brewing
  • Fermentation
  • Bioprocessing
 
For Use With (Equipment) AV88 Universal Analyzer
Type DO (ppm) sensor
Accuracy 1% of reading
Description DO (ppm) sensor
Max. Flow Rate 10 ft./sec.
Max. Pressure 65psig (at 50°C)
Range 0 to 40ppm
Resolution 0.01ppm
Step Response Time 90% in 90 seconds
Temperature (English) Operating 23° to 122°F
Temperature (Metric) Operating -5° to +50°C
Item Description DO (ppm) sensor
Unit Size -

AnalogPlus™ Dissolved Ozone Sensor

Repeatedly perform the most demanding industrial applications with the Thermo Scientific™ AquaSensors™ AnalogPlus™ Dissolved Ozone Sensor. The sensor is a cost-effective solution for use with the AV88 AnalogPlus™ Universal Analyzer.

Features:
  • Replacement membrane caps for long life
  • 0 to 10ppm measurement range
  • 0.01ppm resolution

Recommended for:

  • Drinking water treatment
  • Wastewater treatment
  • Food and beverage sanitization
  • Bottled water production
  • Packaged water systems
  • Pulp and paper bleaching
  • Pharmaceutical
  • Cooling water
  • Semiconductor wash water
 
For Use With (Equipment) AV88 Universal Analyzer
Type Dissolved Ozone Sensor
Accuracy 2%
Description Dissolved Ozone Sensor
Max. Pressure 65psig (at 50°C)
Range 0 to 10ppm
Resolution 0.01ppm
Step Response Time 90% in less than 90 seconds
Temperature (English) Operating 23° to 122°F
Temperature (Metric) Operating -5° to +50°C
Item Description Dissolved ozone sensor
Unit Size -