18, Jalan Sungai Burung U32/U,
Seksyen 32, Bukit Rimau,
40460 Shah Alam,
Selangor Darul Ehsan, Malaysia.
ProDIGITAL ODO/CT Cable AssemblyThe ODO/CT, probe and cable assembly features integral (i.e., built-in) optical dissolved oxygen, conductivity, and temperature sensors and is available in lengths up to 100 meters. It’s perfect for measuring DO in the following applications – estuary, wetland, coastal, aquaculture, or any application requiring accurate, real-time salinity-compensated DO measurements.
The ODO/CT assembly is compatible with the ProSolo, ProSwap, and ProDSS handhelds (sold separately). Pre-assembled ProSolo kits are available. | ProDSS ODO Optical Dissolved Oxygen SensorProDSS Optical Dissolved Oxygen Sensor | YSI MultiLab 4010-3W Three Channel Benchtop Multiparameter Insrtrument with Wireles Capability
Laboratory instrument for DO/BOD, pH, ORP, conductivity and ion activity measurement. EPA approved for drinking water and wastewater compliance reporting.
Connect digital IDS sensors to the MultiLab 4010-3W for the measurement of DO/BOD, pH, ORP, and conductivity in any combination. Ion selective electrodes (ISEs) can also be connected to the instrument. Instrument Only. Cables, probes/sensors, and accessories sold separately. The YSI MultiLab line includes the 4010-1W (single channel), 4010-2W (dual channel) and 4010-3W (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory.
All MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD. ISEs can also be connected to two and three channel instruments.
Intelligent Digital Sensors (IDS) The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.
Wireless Sensors Free yourself from cables! The MultiLab offers wireless sensors for pH, FDO, conductivity, and ORP, giving you freedom to move around your laboratory. The IDS OBOD probe (optical) and the IDS 4100 BOD probe (polarographic) can be used for wastewater compliance reporting of BOD and CBOD. Available IDS pH and conductivity sensors can also be used for drinking water and wastewater compliance reporting. By using the available BNC adapter and the corresponding ISE, the MultiLab 4010-2W and 4010-3W can be used for compliance reporting of Ammonia (wastewater), Bromide (wastewater), Chloride (wastewater), Cyanide (wastewater and drinking water), Fluoride (wastewater and drinking water), Nitrate (wastewater and drinking water), Potassium (wastewater), and Sulfide (wastewater). | YSI MultiLab 4010-2W Two Channel Benchtop Multiparameter Instrument with wireless capabilityLaboratory instrument for DO/BOD, pH, ORP, conductivity and ion activity measurement. EPA approved for drinking water and wastewater compliance reporting.
Connect digital IDS sensors to the MultiLab 4010-2W for the measurement of DO/BOD, pH, ORP, and conductivity in any combination. Ion selective electrodes (ISEs) can also be connected to the instrument. Instrument Only. Cables, probes/sensors, and accessories sold separately. The YSI MultiLab line includes the 4010-1W (single channel), 4010-2W (dual channel) and 4010-3W (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory. All MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD. ISEs can also be connected to two and three channel instruments. Please visit the MultiLab Kits page for fully assembled systems. Features of the MultiLab line:
Intelligent Digital Sensors (IDS) The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.
Wireless Sensors Free yourself from cables! The MultiLab offers wireless sensors for pH, FDO, conductivity, and ORP, giving you freedom to move around your laboratory. The IDS OBOD probe (optical) and the IDS 4100 BOD probe (polarographic) can be used for wastewater compliance reporting of BOD and CBOD. Available IDS pH and conductivity sensors can also be used for drinking water and wastewater compliance reporting. By using the available BNC adapter and the corresponding ISE, the MultiLab 4010-2W and 4010-3W can be used for compliance reporting of Ammonia (wastewater), Bromide (wastewater), Chloride (wastewater), Cyanide (wastewater and drinking water), Fluoride (wastewater and drinking water), Nitrate (wastewater and drinking water), Potassium (wastewater), and Sulfide (wastewater). | ||||||||||||||||||||||||||||||||||||||||||
YSI MultiLab 4010-1W Single Channel Benchtop Multiparameter InstrumentLaboratory instrument for DO/BOD, pH, ORP, and conductivity measurement. EPA approved for drinking water and wastewater compliance reporting. Connect digital IDS sensors to the MultiLab 4010-1W for the measurement of DO/BOD, pH, ORP, and conductivity.
Instrument Only. Cables, probes/sensors, and accessories sold separately. The YSI MultiLab line includes the 4010-1W (single channel), 4010-2W (dual channel) and 4010-3W (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory. All MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD. ISEs can also be connected to two and three channel instruments. Please visit the MultiLab Kits page for fully assembled systems. Features of the MultiLab line:
Intelligent Digital Sensors (IDS) The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.
Wireless Sensors Free yourself from cables! The MultiLab offers wireless sensors for pH, FDO, conductivity, and ORP, giving you freedom to move around your laboratory.
The IDS OBOD probe (optical) and the IDS 4100 BOD probe (polarographic) can be used for wastewater compliance reporting of BOD and CBOD. Available IDS pH and conductivity sensors can also be used for drinking water and wastewater compliance reporting.
| YSI MultiLab 4010P-1W Single Channel Benchtop Multiparameter Instrument with Integrated PrinterLaboratory instrument for DO/BOD, pH, ORP, and conductivity measurement. EPA approved for drinking water and wastewater compliance reporting.
Connect digital IDS sensors to the MultiLab 4010-1W for the measurement of DO/BOD, pH, ORP, and conductivity. Data can be conveniently printed from the instrument via the optional integrated printer (4010P-1W). Instrument Only. Cables, probes/sensors, and accessories sold separately. The YSI MultiLab line includes the 4010-1W (single channel), 4010-2W (dual channel) and 4010-3W (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory. All MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD. ISEs can also be connected to two and three channel instruments. Please visit the MultiLab Kits page for fully assembled systems. Features of the MultiLab line:
Intelligent Digital Sensors (IDS) The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.
Wireless Sensors Free yourself from cables! The MultiLab offers wireless sensors for pH, FDO, conductivity, and ORP, giving you freedom to move around your laboratory.
The IDS OBOD probe (optical) and the IDS 4100 BOD probe (polarographic) can be used for wastewater compliance reporting of BOD and CBOD. Available IDS pH and conductivity sensors can also be used for drinking water and wastewater compliance reporting. | YSI MultiLab IDS KitLaboratory instrument for pH, ORP, conductivity and BOD in any combination. 626570 MultiLab BOD Lab Kit: MultiLab 4010-1 and OBOD probe 626571 MultiLab Advanced BOD Lab Kit: MultiLab 4010-1, OBOD probe, and BOD Analyst Pro PC software 626572 MultiLab pH Lab Kit: MultiLab 4010-1 and pH electrode (dual junction combination electrode with integrated temperature sensor) 626573 MultiLab BOD/pH Lab Kit: MultiLab 4010-2, OBOD probe, and pH electrode (dual junction combination electrode with integrated temperature sensor) 626574 MultiLab Advanced BOD/pH Lab Kit: MultiLab 4010-2, OBOD probe, BOD Analyst Pro PC software, and pH electrode (dual junction combination electrode with integrated temperature sensor)
The YSI MultiLab line includes the 4010-1 (single channel), 4010-2 (dual channel) and 4010-3 (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory. The MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD in the laboratory. In addition, ISEs can be connected to the MultiLab 4010-2 and 4010-3 with the MultiLab BNC Adaptor. MultiLab instrument features:
Intelligent Digital Sensors (IDS) The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.
CMC The CMC function displays continual monitoring of the sensor's measuring range. The range is represented with a bar and calibration points are shown as vertical lines at the cal point. A moving cursor shows the current measured value and indicates if the measurement is within the calibrated range. Quality Sensor Control QSC is a system to monitor the condition of the pH electrode. An initial calibration is performed and, afterwards, the sensor status is monitored and graphically displayed over time. | YSI MultiLab IDS ProOBOD Self-stirring Optical BOD ProbeThe IDS ProOBOD® self-stirring optical BOD probe for use with the YSI MultiLab. Designed to fit into standard 300 mL BOD bottles. EPA approved for wastewater compliance reporting of BOD and CBOD. The ProOBOD is designed for use with all models of the YSI MultiLab, including the 4010-1W, 4010-2W, and 4010-3W. Optical, luminescent technology eliminates the probe warm-up period and membrane changes. The self-stirring BOD probe has a super quiet lab stirrer that helps ensure a representative sample and improves DO response times.
Includes one optical sensor cap. | ||||||||||||||||||||||||||||||||||||||||||
YSI MultiLab IDS 4100 ProBOD Polarographic ProbeSelf-stirring, polarographic, membrane-covered BOD probe Polarographic, membrane-covered BOD Probe, self-stirring, 1.5m (5 ft) cable. The 4100 BOD probe can only be used with the MultiLab 4010-1W, MultiLab 4010-2W, and the MultiLab 4010-3W. It can also be used with the MultiLab 4010-1 if the latest instrument firmware has been installed | YSI TruLab pH/ISE 1320 Dual Channel Benchtop pH/ORP/ISE InstrumentLaboratory Instrument for pH, mV (ORP), and Ion Activity Measurement
Measure pH, ORP, and ion activity with the TruLab 1320 dual channel instrument by choosing from our wide selection of electrodes. The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory. Measure pH, mV (ORP), ISE and temperature accurately in the laboratory with the YSI pH 1320 or 1320P with built-in printer. The TruLab pH/ISE 1320 benchtop meter is the ideal laboratory instrument for reliable measurements with automatic documentation for GLP compliance. The 1320 has internal memory. Stored data can be sent to a PC via USB or to an optional built-in printer available on the 1320P. TruLab 1320 Features:
Parameters:
In addition to pH, the TruLab 1320 can be used for compliance reporting of Ammonia (wastewater), Bromide (wastewater), Chloride (wastewater), Cyanide (wastewater and drinking water), Fluoride (wastewater and drinking water), Nitrate (wastewater and drinking water), Potassium (wastewater), and Sulfide (wastewater). Repeatable/Efficient The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability. Convenient/Reliable An adjustable timer indicates when to perform the next calibration routine, improving measurement accuracy. | YSI TruLab pH/ISE 1320P Dual Channel Benchtop pH/ORP/ISE Instrument with Integral PrinterLaboratory Instrument for pH, mV (ORP), and Ion Activity Measurement
Measure pH, ORP, and ion activity with the TruLab 1320 dual channel instrument by choosing from our wide selection of electrodes. Data can be conveniently printed from the instrument via the optional integrated printer (1320P). EPA approved for drinking water and wastewater compliance reporting.
Instrument Only. Cables, probes/sensors, and accessories sold separately. The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory. Measure pH, mV (ORP), ISE and temperature accurately in the laboratory with the YSI pH 1320 or 1320P with built-in printer. The TruLab pH/ISE 1320 benchtop meter is the ideal laboratory instrument for reliable measurements with automatic documentation for GLP compliance. The 1320 has internal memory. Stored data can be sent to a PC via USB or to an optional built-in printer available on the 1320P. Features:
Parameters:
In addition to pH, the TruLab 1320 can be used for compliance reporting of Ammonia (wastewater), Bromide (wastewater), Chloride (wastewater), Cyanide (wastewater and drinking water), Fluoride (wastewater and drinking water), Nitrate (wastewater and drinking water), Potassium (wastewater), and Sulfide (wastewater). Repeatable/Efficient The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability. Convenient/Reliable
An adjustable timer indicates when to perform the next calibration routine, improving measurement accuracy.
| YSI TruLab pH 1310 Single Channel pH, mV(ORP) Benchtop InstrumentLaboratory Instrument for pH, mV (ORP) and temperature
EPA approved for drinking water and wastewater compliance reporting of pH. Instrument Only. Cables, probes/sensors, and accessories sold separately. The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory. Measure pH, mV (ORP) and temperature accurately in the laboratory with the YSI pH 1310 or 1310P with built-in printer. The TruLab pH 1310 benchtop meter is the ideal laboratory instrument for reliable pH/mV measurements with automatic documentation for GLP compliance. The 1310 benchtop is an accurate, easy-to-use solution for the measurement of pH or mv (ORP) in the laboratory. Available with or without a built-in printer. The 1310 has internal memory. Stored data can be sent to a PC via USB or to an optional built-in printer available on the 1310P. Features:
Repeatable/Efficient The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability. Convenient/Reliable Data can be printed directly from the instrument via the integrated printer or exported via USB.
Includes instrument, universal AC power supply, electrode stand, USB cable and PC software. | ||||||||||||||||||||||||||||||||||||||||||
YSI TruLab pH 1310P Single Channel pH and mV (ORP) Benchtop Instrument with Integrated PrinterLaboratory Instrument for pH, mV (ORP) and temperature.Perform accurate lab pH, mV (ORP) and temperature measurements with the YSI 1310 and 1310P with printer.
Instrument Only. Cables, probes/sensors, and accessories sold separately. The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory. The TruLab pH 1310 benchtop meter is the ideal laboratory instrument for reliable pH/mV (ORP) measurements with automatic documentation for GLP compliance. Available with or without a built-in printer. The 1310 has internal memory. Stored data can be sent to a PC via USB or to an optional built-in printer available on the 1310P. Features:
Wide selection of electrodes - pH, ORP and temperature probes Repeatable/Efficient The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability.
Convenient/Reliable data can be printed directly from the instrument via the integrated printer or exported via USB. | YSI TruLab pH 1110 Singel Channel pH/mV Benchtop Instrument with BNC and Two Banana Plug ConnectorsLaboratory Benchtop pH meter for pH, mV (ORP) and temperature
EPA approved for drinking water and wastewater compliance reporting of pH.
Instrument Only. Cables, probes/sensors, and accessories sold separately. The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory. Measure pH, mV (ORP) and temperature accurately in the laboratory with the YSI pH 1110. This benchtop instrument for basic, routine measurements in the lab is an accurate and easy-to-use solution for repeatable pH or mV measurements. Features:
Repeatable/Efficient The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability. Convenient/Reliable
An adjustable timer indicates when to perform the next calibration routine, improving measurement accuracy. | YSI EcoSense pH1000A Benchtop pH/mV(ORP) MeterThe EcoSense® pH1000A benchtop pH meter provides accurate measurements in an affordable format. The instrument features an easy-to-use interface and 1, 2, or 3 point pH calibration. In addition to pH, the pH1000A also measures mV (ORP) and temperature. The pH1000A benchtop pH meter is an economical, accurate and easy-to-use solution for basic, routine pH or mV measurements in the lab. The AUTOLOCK feature locks stable measurements on the display, resulting in precise, repeatable, and error-free measurements. Simple calibration procedures, automatic buffer recognition, and electrode efficiency display makes calibration quick and easy. The following pH1000A purchase options are available:
Features of the pH1000A include:
* If not using the 1102 pH electrode with a built-in temperature sensor, the 1103 temperature sensor will need to be used for automatic temperature compensation. | MultiLab 4011 BOD AdapterCable for connecting YSI 5010 BOD probe to MultiLab | ||||||||||||||||||||||||||||||||||||||||||
MultiLab FDO 4410W IDS Wireless SensorWireless fluorescent dissolved oxygen (FDO) probe with temperature | MultiLab FDO 4410 IDS SensorFluorescent dissolved oxygen (FDO) probe with temperature sensor | MultiLab IDS 4120W pH and Temperature Wireless SensorWireless pH and temperature, plastic, 3 mol KCl, digital, double junction probe with refillable reference | MultiLab IDS 4310W Conductivity and Temperature Wireless SensorWireless conductivity and temperature, epoxy body, 4-graphite electrodes, digital probe, K= 0.475 cm-1 | ||||||||||||||||||||||||||||||||||||||||||
MultiLab IDS 4320W Conductivity and Temperature Wireless SensorWireless conductivity and temperature, stainless steel body, 2-electrodes, digital probe, K = 0.1 cm-1 | MultiLab IDS 4110W pH and Temperature Wireless SensorWireless pH and temperature, plastic, gel, digital, double junction probe | MultiLab IDS 4130W pH and Temperature Wireless SensorWireless pH and temperature, glass, 3 mol KCL, digital, double junction probe with refillable reference | MultiLab IDS 4210W ORP Wireless SensorWireless ORP, glass, 3 mol KCl, digital, double junction probe with refillable reference |