YSI MultiLab 4010-3W Three Channel Benchtop Multiparameter Insrtrument with Wireles Capability

Laboratory instrument for DO/BOD, pH, ORP, conductivity and ion activity measurement. EPA approved for drinking water and wastewater compliance reporting.

Connect digital IDS sensors to the MultiLab 4010-3W for the measurement of DO/BOD, pH, ORP, and conductivity in any combination. Ion selective electrodes (ISEs) can also be connected to the instrument.

Instrument Only.  Cables, probes/sensors, and accessories sold separately.

The YSI MultiLab line includes the 4010-1W (single channel), 4010-2W (dual channel) and 4010-3W (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory.

 

All MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD. ISEs can also be connected to two and three channel instruments.

Features of the MultiLab line:

  • Input for pH, ORP, DO/BOD (optical or polarographic), or conductivity sensors
  • ISEs with BNC connection can be connected to the MultiLab 4010-2W and 4010-3W with an adapter (108132Y) that converts one digital input to an analog BNC input (i.e. only one ISE can be connected)
  • Built-in OUR/SOUR software on the MultiLab 4010-2W and 4010-3W
  • Wireless sensors available for the MultiLab 4010-1W, 4010-2W, and 4010-3W
  • Data storage - 500 data sets in manual mode and 5,000 (MultiLab 4010-1W) or 10,000 (MultiLab 4010-2W and 4010-3W) data sets in automatic logging mode
  • Large, easy to read graphic display
  • Color screen and antibacterial keypad on MultiLab 4010-2W and 4010-3W instruments
  • Intelligent, digital sensors - plug and play connectivity
  • GLP traceability (sensors store serial # and calibration data)
  • USB connectivity to manage data; USB cable included
  • PC software included for easy data transfer
  • Durable electrode stand included
  • 3-year warranty

Intelligent Digital Sensors (IDS)

The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.

  • Plug and play connectivity with each instrument
  • IDS sensors store their own unique ID with serial number and calibration data
  • Digital sensor recognition, processing and data transfer
  • Includes self-stirring BOD (optical or polarographic), fluorescent dissolved oxygen (FDO), pH, ORP and conductivity sensors

Wireless Sensors

Free yourself from cables! The MultiLab offers wireless sensors for pH, FDO, conductivity, and ORP, giving you freedom to move around your laboratory.

EPA Approved Methodology

The IDS OBOD probe (optical) and the IDS 4100 BOD probe (polarographic) can be used for wastewater compliance reporting of BOD and CBOD. Available IDS pH and conductivity sensors can also be used for drinking water and wastewater compliance reporting.

By using the available BNC adapter and the corresponding ISE, the MultiLab 4010-2W and 4010-3W can be used for compliance reporting of Ammonia (wastewater), Bromide (wastewater), Chloride (wastewater), Cyanide (wastewater and drinking water), Fluoride (wastewater and drinking water), Nitrate (wastewater and drinking water), Potassium (wastewater), and Sulfide (wastewater). 

YSI MultiLab 4010-2W Two Channel Benchtop Multiparameter Instrument with wireless capability

Laboratory instrument for DO/BOD, pH, ORP, conductivity and ion activity measurement. EPA approved for drinking water and wastewater compliance reporting.

Connect digital IDS sensors to the MultiLab 4010-2W for the measurement of DO/BOD, pH, ORP, and conductivity in any combination. Ion selective electrodes (ISEs) can also be connected to the instrument.

Instrument Only.  Cables, probes/sensors, and accessories sold separately.

The YSI MultiLab line includes the 4010-1W (single channel), 4010-2W (dual channel) and 4010-3W (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory.

All MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD. ISEs can also be connected to two and three channel instruments.

Please visit the MultiLab Kits page for fully assembled systems.

Features of the MultiLab line:

  • Input for pH, ORP, DO/BOD (optical or polarographic), or conductivity sensors
  • ISEs with BNC connection can be connected to the MultiLab 4010-2W and 4010-3W with an adapter (108132Y) that converts one digital input to an analog BNC input (i.e. only one ISE can be connected)
  • Built-in OUR/SOUR software on the MultiLab 4010-2W and 4010-3W
  • Wireless sensors available for the MultiLab 4010-1W, 4010-2W, and 4010-3W
  • Data storage - 500 data sets in manual mode and 5,000 (MultiLab 4010-1W) or 10,000 (MultiLab 4010-2W and 4010-3W) data sets in automatic logging mode
  • Large, easy to read graphic display
  • Color screen and antibacterial keypad on MultiLab 4010-2W and 4010-3W instruments
  • Intelligent, digital sensors - plug and play connectivity
  • GLP traceability (sensors store serial # and calibration data)
  • USB connectivity to manage data; USB cable included
  • PC software included for easy data transfer
  • Durable electrode stand included
  • 3-year warranty

Intelligent Digital Sensors (IDS)

The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.

  • Plug and play connectivity with each instrument
  • IDS sensors store their own unique ID with serial number and calibration data
  • Digital sensor recognition, processing and data transfer
  • Includes self-stirring BOD (optical or polarographic), fluorescent dissolved oxygen (FDO), pH, ORP and conductivity sensors

Wireless Sensors

Free yourself from cables! The MultiLab offers wireless sensors for pH, FDO, conductivity, and ORP, giving you freedom to move around your laboratory.

EPA Approved Methodology

The IDS OBOD probe (optical) and the IDS 4100 BOD probe (polarographic) can be used for wastewater compliance reporting of BOD and CBOD. Available IDS pH and conductivity sensors can also be used for drinking water and wastewater compliance reporting.

By using the available BNC adapter and the corresponding ISE, the MultiLab 4010-2W and 4010-3W can be used for compliance reporting of Ammonia (wastewater), Bromide (wastewater), Chloride (wastewater), Cyanide (wastewater and drinking water), Fluoride (wastewater and drinking water), Nitrate (wastewater and drinking water), Potassium (wastewater), and Sulfide (wastewater). 


YSI MultiLab 4010-1W Single Channel Benchtop Multiparameter Instrument

Laboratory instrument for DO/BOD, pH, ORP, and conductivity measurement. EPA approved for drinking water and wastewater compliance reporting.

Connect digital IDS sensors to the MultiLab 4010-1W for the measurement of DO/BOD, pH, ORP, and conductivity.

Instrument Only.  Cables, probes/sensors, and accessories sold separately.
 

The YSI MultiLab line includes the 4010-1W (single channel), 4010-2W (dual channel) and 4010-3W (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory. All MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD. ISEs can also be connected to two and three channel instruments.

Please visit the MultiLab Kits page for fully assembled systems.

Features of the MultiLab line:

  • Input for pH, ORP, DO/BOD, or conductivity sensors
  • ISEs with BNC connection can be connected to the MultiLab 4010-2W and 4010-3W with an adapter (108132Y) that converts one digital input to an analog BNC input (i.e. only one ISE can be connected)
  • Built-in OUR/SOUR software on the MultiLab 4010-2W and 4010-3W
  • Wireless sensors available for the MultiLab 4010-1W, 4010-2W, and 4010-3W
  • Data storage - 500 data sets in manual mode and 5,000 (MultiLab 4010-1W) or 10,000 (MultiLab 4010-2W and 4010-3W) data sets in automatic logging mode
  • Large, easy to read graphic display
  • Color screen and antibacterial keypad on MultiLab 4010-2W and 4010-3W instruments
  • Intelligent, digital sensors - plug and play connectivity
  • GLP traceability (sensors store serial # and calibration data)
  • USB connectivity to manage data; USB cable included
  • PC software included for easy data transfer
  • Durable electrode stand included
  • 3-year warranty

Intelligent Digital Sensors (IDS)

The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.

  • Plug and play connectivity with each instrument
  • IDS sensors store their own unique ID with serial number and calibration data
  • Digital sensor recognition, processing and data transfer
  • Includes self-stirring BOD (optical or polarographic), fluorescent dissolved oxygen (FDO), pH, ORP and conductivity sensors

Wireless Sensors

Free yourself from cables! The MultiLab offers wireless sensors for pH, FDO, conductivity, and ORP, giving you freedom to move around your laboratory.

EPA Approved Methodology

 

The IDS OBOD probe (optical) and the IDS 4100 BOD probe (polarographic) can be used for wastewater compliance reporting of BOD and CBOD. Available IDS pH and conductivity sensors can also be used for drinking water and wastewater compliance reporting.


 

YSI MultiLab 4010P-1W Single Channel Benchtop Multiparameter Instrument with Integrated Printer

Laboratory instrument for DO/BOD, pH, ORP, and conductivity measurement. EPA approved for drinking water and wastewater compliance reporting. 

Connect digital IDS sensors to the MultiLab 4010-1W for the measurement of DO/BOD, pH, ORP, and conductivity. Data can be conveniently printed from the instrument via the optional integrated printer (4010P-1W).

Instrument Only.  Cables, probes/sensors, and accessories sold separately.

The YSI MultiLab line includes the 4010-1W (single channel), 4010-2W (dual channel) and 4010-3W (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory. All MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD. ISEs can also be connected to two and three channel instruments.

Please visit the MultiLab Kits page for fully assembled systems.

Features of the MultiLab line:

  • Input for pH, ORP, DO/BOD, or conductivity sensors
  • ISEs with BNC connection can be connected to the MultiLab 4010-2W and 4010-3W with an adapter (108132Y) that converts one digital input to an analog BNC input (i.e. only one ISE can be connected)
  • Built-in OUR/SOUR software on the MultiLab 4010-2W and 4010-3W
  • Wireless sensors available for the MultiLab 4010-1W, 4010-2W, and 4010-3W
  • Data storage - 500 data sets in manual mode and 5,000 (MultiLab 4010-1W) or 10,000 (MultiLab 4010-2W and 4010-3W) data sets in automatic logging mode
  • Large, easy to read graphic display
  • Color screen and antibacterial keypad on MultiLab 4010-2W and 4010-3W instruments
  • Intelligent, digital sensors - plug and play connectivity
  • GLP traceability (sensors store serial # and calibration data)
  • USB connectivity to manage data; USB cable included
  • PC software included for easy data transfer
  • Durable electrode stand included
  • 3-year warranty

Intelligent Digital Sensors (IDS)

The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.

  • Plug and play connectivity with each instrument
  • IDS sensors store their own unique ID with serial number and calibration data
  • Digital sensor recognition, processing and data transfer
  • Includes self-stirring BOD (optical or polarographic), fluorescent dissolved oxygen (FDO), pH, ORP and conductivity sensors

Wireless Sensors

Free yourself from cables! The MultiLab offers wireless sensors for pH, FDO, conductivity, and ORP, giving you freedom to move around your laboratory.

EPA Approved Methodology

 

The IDS OBOD probe (optical) and the IDS 4100 BOD probe (polarographic) can be used for wastewater compliance reporting of BOD and CBOD. Available IDS pH and conductivity sensors can also be used for drinking water and wastewater compliance reporting.

YSI MultiLab IDS Kit

Laboratory instrument for pH, ORP, conductivity and BOD in any combination.

626570 MultiLab BOD Lab Kit: MultiLab 4010-1 and OBOD probe

626571 MultiLab Advanced BOD Lab Kit: MultiLab 4010-1, OBOD probe, and BOD Analyst Pro PC software

626572 MultiLab pH Lab Kit: MultiLab 4010-1 and pH electrode (dual junction combination electrode with integrated temperature sensor)

626573 MultiLab BOD/pH Lab Kit: MultiLab 4010-2, OBOD probe, and pH electrode (dual junction combination electrode with integrated temperature sensor)

626574 MultiLab Advanced BOD/pH Lab Kit: MultiLab 4010-2, OBOD probe, BOD Analyst Pro PC software, and pH electrode (dual junction combination electrode with integrated temperature sensor)

 

The YSI MultiLab line includes the 4010-1 (single channel), 4010-2 (dual channel) and 4010-3 (three channel) instruments providing easy to use and calibrate menu-driven operation ideal for the laboratory.

The MultiLab instruments can accurately measure pH, ORP, conductivity, and DO/BOD in the laboratory. In addition, ISEs can be connected to the MultiLab 4010-2 and 4010-3 with the MultiLab BNC Adaptor.

MultiLab instrument features:

  • Input for pH, ORP, DO/BOD, or conductivity sensors
  • Data storage - 500 data sets in manual mode and 5,000 (MultiLab 4010-1) or 10,000 (MultiLab 4010-2/3) data sets in automatic logging mode.
  • Large, easy to read graphic display. MultiLab 4010-2/3 feature a color screen
  • Antibacterial keypad on the MultiLab 4010-2/3
  • Intelligent, digital sensors - plug and play sensors
  • GLP traceability (sensors store serial # and calibration data)
  • USB connectivity to manage data
  • 3-year warranty

Intelligent Digital Sensors (IDS)

The IDS sensors automatically store their unique serial number and calibration data. In addition, they also digitally process the measurement signal. The sensors can be moved from instrument to instrument and maintain their calibration data and transmit this information to the new instrument.

  • Plug and play connectivity with each instrument
  • IDS senors store their own unique ID with serial number and calibration data
  • Digital sensor recognition, processing and data transfer
  • Includes self-stirring BOD, pH, ORP and conductivity sensors
  • BOD probe uses optical dissolved oxygen technology and includes a guarded sensor tip

CMC

The CMC function displays continual monitoring of the sensor's measuring range. The range is represented with a bar and calibration points are shown as vertical lines at the cal point. A moving cursor shows the current measured value and indicates if the measurement is within the calibrated range.

Quality Sensor Control

QSC is a system to monitor the condition of the pH electrode. An initial calibration is performed and, afterwards, the sensor status is monitored and graphically displayed over time.

YSI MultiLab IDS ProOBOD Self-stirring Optical BOD Probe

The IDS ProOBOD® self-stirring optical BOD probe for use with the YSI MultiLab. Designed to fit into standard 300 mL BOD bottles. EPA approved for wastewater compliance reporting of BOD and CBOD.

The ProOBOD is designed for use with all models of the YSI MultiLab, including the 4010-1W4010-2W, and 4010-3W. Optical, luminescent technology eliminates the probe warm-up period and membrane changes. The self-stirring BOD probe has a super quiet lab stirrer that helps ensure a representative sample and improves DO response times.

  • Smart sensor retains calibration in the probe; IDS = Intelligent Digital Sensor
  • User-replaceable, low-maintenance sensor cap with 1-year life
  • 2-year warranty; reliable and serviceable, design reduces cost-of-ownership and reduces down-time
  • Guarded sensor - the sensor guard provides protection of the sensor tip when taking the BOD probe in and out of BOD bottles
  • Probe body tapered to fit into a standard 300 mL BOD bottle
  • Extremely quiet operation
  • No warm-up time required
  • Self-stirring to provide representative sample and increase response times

Includes one optical sensor cap. 

YSI MultiLab IDS 4100 ProBOD Polarographic Probe

Self-stirring, polarographic, membrane-covered BOD probe

Polarographic, membrane-covered BOD Probe, self-stirring, 1.5m (5 ft) cable.

The 4100 BOD probe can only be used with the MultiLab 4010-1W, MultiLab 4010-2W, and the MultiLab 4010-3W. It can also be used with the MultiLab 4010-1 if the latest instrument firmware has been installed

YSI TruLab pH/ISE 1320 Dual Channel Benchtop pH/ORP/ISE Instrument

Laboratory Instrument for pH, mV (ORP), and Ion Activity Measurement

Measure pH, ORP, and ion activity with the TruLab 1320 dual channel instrument by choosing from our wide selection of electrodes.
 

The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory.

Measure pH, mV (ORP), ISE and temperature accurately in the laboratory with the YSI pH 1320 or 1320P with built-in printer. The TruLab pH/ISE 1320 benchtop meter is the ideal laboratory instrument for reliable measurements with automatic documentation for GLP compliance.

The 1320 has internal memory. Stored data can be sent to a PC via USB or to an optional built-in printer available on the 1320P.

TruLab 1320 Features:

  • Simultaneous dual measurement of pH, mV (ORP) or ISE and temperature (2-channel benchtop meter)
  • AutoRead function improves repeatability
  • Easy-to-read backlit display with text menu for easy operation for pH, mV (ORP), ISE and temperature
  • Fast data transfer via USB in .csv or ASCII format or the optional integrated printer
  • Easy calibration with adjustable calibration timer
  • Automatic or manual temperature compensation
  • 1, 2, 3, 4 or 5 point calibration for pH
  • 1, 2, 3, 4, 5, 6 or 7 point calibration for ISE, also non- linear
  • BNC connection for pH, mV and ISEs; banana connection for temperature probes
  • Continuous Monitoring Control (CMC) function for monitoring the ideal measuring range for pH measurements based on the last calibration
  • 3-year warranty
  • GLP/AQA compliant
  • Wide selection of electrodes - pH, ORP, ISE and temperature probes
  • PC software, USB cable, and electrode stand included

Parameters:

  • pH, mV (ORP/Redox)
  • Temperature
  • ISEs: Ammonia, Ammonium, Bromide, Cadmium, Calcium, Chloride, Copper, Cyanide, Fluoride, Iodide, Lead, Nitrate, Potassium, Silver/Sulfide, Sodium

EPA Approved Methodology

In addition to pH, the TruLab 1320 can be used for compliance reporting of Ammonia (wastewater), Bromide (wastewater), Chloride (wastewater), Cyanide (wastewater and drinking water), Fluoride (wastewater and drinking water), Nitrate (wastewater and drinking water), Potassium (wastewater), and Sulfide (wastewater). 

Repeatable/Efficient

The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability.

Convenient/Reliable

An adjustable timer indicates when to perform the next calibration routine, improving measurement accuracy.

YSI TruLab pH/ISE 1320P Dual Channel Benchtop pH/ORP/ISE Instrument with Integral Printer

Laboratory Instrument for pH, mV (ORP), and Ion Activity Measurement

Measure pH, ORP, and ion activity with the TruLab 1320 dual channel instrument by choosing from our wide selection of electrodes. Data can be conveniently printed from the instrument via the optional integrated printer (1320P).

EPA approved for drinking water and wastewater compliance reporting.

Instrument Only.  Cables, probes/sensors, and accessories sold separately.
 

The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory.

Measure pH, mV (ORP), ISE and temperature accurately in the laboratory with the YSI pH 1320 or 1320P with built-in printer. The TruLab pH/ISE 1320 benchtop meter is the ideal laboratory instrument for reliable measurements with automatic documentation for GLP compliance.

The 1320 has internal memory. Stored data can be sent to a PC via USB or to an optional built-in printer available on the 1320P.

Features:

  • Simultaneous dual measurement of pH, mV (ORP) or ISE and temperature (2-channel benchtop meter)
  • AutoRead function improves repeatability
  • Easy-to-read backlit display with text menu for easy operation for pH, mV (ORP), ISE and temperature
  • Fast data transfer via USB in .csv or ASCII format or the optional integrated printer
  • Easy calibration with adjustable calibration timer Automatic or manual temperature compensation
  • 1, 2, 3, 4 or 5 point calibration for pH
  • 1, 2, 3, 4, 5, 6 or 7 point calibration for ISE, also non- linear
  • BNC connection for pH, mV and ISEs; banana connection for temperature probes
  • Continuous Monitoring Control (CMC) function for monitoring the ideal measuring range for pH measurements based on the last calibration
  • 3-year warranty
  • GLP/AQA compliant
  • Wide selection of electrodes - pH, ORP, ISE and temperature probes
  • PC software, USB cable, and electrode stand included

Parameters:

  • pH, mV (ORP/Redox)
  • Temperature
  • ISEs: Ammonia, Ammonium, Bromide, Cadmium, Calcium, Chloride, Copper, Cyanide, Fluoride, Iodide, Lead, Nitrate, Potassium, Silver/Sulfide, Sodium

EPA Approved Methodology

In addition to pH, the TruLab 1320 can be used for compliance reporting of Ammonia (wastewater), Bromide (wastewater), Chloride (wastewater), Cyanide (wastewater and drinking water), Fluoride (wastewater and drinking water), Nitrate (wastewater and drinking water), Potassium (wastewater), and Sulfide (wastewater). 

Repeatable/Efficient

The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability.

Convenient/Reliable

 

An adjustable timer indicates when to perform the next calibration routine, improving measurement accuracy.

Specifications:

Benchtop Yes
Buffer Recognition Yes
Certifications IP43, cETLus, electrical protective class III, CE
Display Backlit graphic display
Equipment used with TruLab analog pH/mV/ISE/temp probes
GLP Compliance Yes
Graphic Display Backlit graphic display
Logging Capabilities Yes
Measurement Method / Channels 2 Channel
Measurement Range Ranges Resolutions Accuracy (+1 digit) pH -2.0 to 20.0; -2.00 to 20.00; -2.000 to 19.999 0.1; 0.01; 0.001 ±0.1; ±0.01; ±0.005 (temp of test sample 15 to 35°C; within a range of ±2 pH of the calibration point) mV -1200 to 1200.0; -2500 to 2500 0.1; 1.0 ±0.3; ±1.0 (temp of test sample 15 to 35°C) ISE (mg/l, mg/kg, mmol/l, ppm, %) (µmol/l) 0.000 to 9.999; 10.00 to 99.99; 100.0 to 999.9; 1000 to 999999 0.000 to 9.999; 10.00 to 99.99; 100.0 to 999.9; 1000 to 9999 0.001; 0.01; 0.1; 1 Temperature -5 to 105°C (23.0 to 221°F) 0.1 ±0.1
Memory 500 data sets manual logging, 5,000 data sets auto logging
Operating pH Range -2.000 to 19.999, -2.00 to 20.00, -2.0 to 20.0
Operating Temperature -5 to 105°C, 23.0 to 221°F
Parameters Measured pH, ORP (mV), Ammonia, Ammonium, Bromide, Cadmium, Calcium, Chloride, Copper, Cyanide, Fluoride, Iodide, Lead, Nitrate, Potassium, Silver/Sulfide, Sodium, Temperature
Power 4 alkaline AA batteries fully charged or included universal power supply, approximately 150 hours with illumination or 1000 without
Sampling Yes
Storage Temperature -13 to 149°F, -25 to 65°C
Unit of Measure Known addition (double), ISE Measurements: Blank value correction, increment methods: Known addition (single), Sample subtraction, Known subtraction, Sample addition
User Calibratable Yes
User Replaceable Yes
Warranty 3 years

YSI TruLab pH 1310 Single Channel pH, mV(ORP) Benchtop Instrument

Laboratory Instrument for pH, mV (ORP) and temperature


Perform accurate lab pH, mV (ORP) and temperature measurements with the YSI 1310 and 1310P with printer.

EPA approved for drinking water and wastewater compliance reporting of pH.

Instrument Only.  Cables, probes/sensors, and accessories sold separately.

The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory.

Measure pH, mV (ORP) and temperature accurately in the laboratory with the YSI pH 1310 or 1310P with built-in printer.

The TruLab pH 1310 benchtop meter is the ideal laboratory instrument for reliable pH/mV measurements with automatic documentation for GLP compliance. The 1310 benchtop is an accurate, easy-to-use solution for the measurement of pH or mv (ORP) in the laboratory. Available with or without a built-in printer. The 1310 has internal memory. Stored data can be sent to a PC via USB or to an optional built-in printer available on the 1310P.

Features:

  • Single channel measurement of pH or mV (ORP) and temperature
  • AutoRead function improves repeatability
  • Easy-to-read backlit display with text menu for easy operation for pH, mV (ORP) and temperature
  • Fast data transfer via USB in .csv or ASCII format or the optional integrated printer
  • Easy calibration with adjustable calibration timer
  • Automatic or manual temperature compensation
  • 1, 2, 3, 4 or 5 point calibration for pH; 22 stored buffer sets for auto-buffer recognition and easy calibration
  • BNC connection for pH, mV; banana connection for temperature probes
  • Continuous Monitoring Control (CMC) function for monitoring the ideal measuring range for pH measurements based on the last calibration
  • 3-year warranty GLP/AQA compliant
  • Wide selection of electrodes - pH, ORP and temperature probes

Repeatable/Efficient

The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability.

Convenient/Reliable

Data can be printed directly from the instrument via the integrated printer or exported via USB.

 

Includes instrument, universal AC power supply, electrode stand, USB cable and PC software.

YSI TruLab pH 1310P Single Channel pH and mV (ORP) Benchtop Instrument with Integrated Printer

Laboratory Instrument for pH, mV (ORP) and temperature.Perform accurate lab pH, mV (ORP) and temperature measurements with the YSI 1310 and 1310P with printer.


EPA approved for drinking water and wastewater compliance reporting of pH.

Instrument Only.  Cables, probes/sensors, and accessories sold separately.
 

The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory.

The TruLab pH 1310 benchtop meter is the ideal laboratory instrument for reliable pH/mV (ORP) measurements with automatic documentation for GLP compliance.

Available with or without a built-in printer. The 1310 has internal memory. Stored data can be sent to a PC via USB or to an optional built-in printer available on the 1310P.

Features:

  • Single channel measurement of pH or mV (ORP) and temperature
  • AutoRead function improves repeatability
  • Easy-to-read backlit display with text menu for easy operation for pH, mV (ORP) and temperature
  • Fast data transfer via USB in .csv or ASCII format or the optional integrated printer
  • Easy calibration with adjustable calibration timer
  • Automatic or manual temperature compensation
  • 1, 2, 3, 4 or 5 point calibration for pH; 22 stored buffer sets for auto-buffer recognition and easy calibration
  • BNC connection for pH, mV; banana connection for temperature probes
  • Continuous Monitoring Control (CMC) function for monitoring the ideal measuring range for pH measurements based on the last calibration
  • 3-year warranty
  • GLP/AQA compliant
  • PC software, USB cable, and electrode stand included

Wide selection of electrodes - pH, ORP and temperature probes

Repeatable/Efficient The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability.

 

Convenient/Reliable data can be printed directly from the instrument via the integrated printer or exported via USB.

YSI TruLab pH 1110 Singel Channel pH/mV Benchtop Instrument with BNC and Two Banana Plug Connectors

Laboratory Benchtop pH meter for pH, mV (ORP) and temperature


Perform accurate lab pH, mV (ORP) and temperature measurements with the YSI 1110.  TruLab 1110 pH/mV single channel benchtop instrument with BNC and two banana plug connectors. Includes instrument, universal AC power supply and electrode stand.

EPA approved for drinking water and wastewater compliance reporting of pH.

Instrument Only.  Cables, probes/sensors, and accessories sold separately.
 

The YSI TruLab line includes the 1110 (single channel), 1310 and 1310P (single channel) and 1320 and 1320P (dual channel) instruments providing easy-to-use and calibrate instruments ideal for the laboratory.

Measure pH, mV (ORP) and temperature accurately in the laboratory with the YSI pH 1110. This benchtop instrument for basic, routine measurements in the lab is an accurate and easy-to-use solution for repeatable pH or mV measurements.

Features:

  • Single channel measurement of pH or mV (ORP) and temperature
  • AutoRead function improves repeatability
  • Easy-to-read large, segmented display for pH, mV (ORP) and temperature
  • Easy calibration with adjustable calibration timer
  • Automatic or manual temperature compensation
  • 1, 2 or 3-point calibration
  • BNC connection for pH, mV; banana connection for temperature probes
  • 3-year warranty
  • Wide selection of electrodes - pH, ORP and temperature probes

Repeatable/Efficient

The instrument's AutoRead function indicates when a stable measurement is reached improving repeatability.

Convenient/Reliable

 

An adjustable timer indicates when to perform the next calibration routine, improving measurement accuracy.

YSI EcoSense pH1000A Benchtop pH/mV(ORP) Meter

The EcoSense® pH1000A benchtop pH meter provides accurate measurements in an affordable format. The instrument features an easy-to-use interface and 1, 2, or 3 point pH calibration. In addition to pH, the pH1000A also measures mV (ORP) and temperature.

The pH1000A benchtop pH meter is an economical, accurate and easy-to-use solution for basic, routine pH or mV measurements in the lab. The AUTOLOCK feature locks stable measurements on the display, resulting in precise, repeatable, and error-free measurements. Simple calibration procedures, automatic buffer recognition, and electrode efficiency display makes calibration quick and easy.

The following pH1000A purchase options are available:

  • 601100: pH1000A instrument only
  • 601104: pH1000A instrument and electrode stand
  • 601305: pH1000A instrument, 1102 pH/ATC probe with built-in temperature sensor, and electrode stand
  • 601306: pH1000A instrument and 1102 pH/ATC probe with built-in temperature sensor

Features of the pH1000A include:

  • Measures pH, mV (ORP), and temperature
  • Large, high-contrast, LCD display
  • Simple 1, 2, or 3 point calibration
  • AUTOLOCK mode holds stable readings on the display
  • Accepts U.S. (7.00, 4.01, 10.01) or NIST (6.86, 4.00, 9.18) buffer sets
  • Automatic or manual temperature compensation of all pH measurements
  • Calibration is stored in memory; view electrode efficiency at any time
  • BNC input allows for any pH or ORP electrode with BNC to be connected*
  • Battery or AC power

* If not using the 1102 pH electrode with a built-in temperature sensor, the 1103 temperature sensor will need to be used for automatic temperature compensation.

   