LELab Sdn Bhd
18, Jalan Sungai Burung U32/U,
Seksyen 32, Bukit Rimau,
40460 Shah Alam,
Selangor Darul Ehsan, Malaysia.
+603-5525 3833
+603-5525 3832

Thermo Scientific AquaSensors™

AquaClear™ DataStick™ Low-Level Turbidimeter


Monitor water turbidity with the Thermo Scientific™ AquaSensors™ AquaClear™ DataStick™ Low-Level Turbidimeter, which may be used with any Thermo Scientific sensor head and can communicate directly with industrial computer systems.

Features:
  • Utilizes a precalibrated optical DataStick technology and unique sample chamber to meet or exceed USEPA Method 180.1
  • Offers 0.001 NTU resolution
  • Low flow rate and 135mL sample chamber limits calibration solution usage
  • Integral temperature measurement and plug-and-play communication adapters

Recommended for:

  • Drinking water
  • Filter monitoring membrane filtration
  • Distribution monitoring
  • Wastewater effluent (clarified)
  • Packaged water systems
  • Food and beverage process

AquaTrace™ ppb Dissolved Oxygen System


Monitor trace oxygen levels in critical processes to allow quick response and minimize costly downtime with the Thermo Scientific™ AquaTrace™ ppb Dissolved Oxygen System, a trace dissolved oxygen sensor that measures accurately in pure water processes. Best performance is achieved when used in applications where process temperature, flow and pressure are stable.

Features:

  • Reagent-free amperometric design
  • Trace DO system includes Trace DO Thermo Scientific™ DataStick™, flow cell, AV38 local display; assembled on the panel for simple installation
  • Temperature compensated
  • Pre-calibrated, plug & play sensors
  • Rugged membrane in replaceable sensor cap
  • Remote measurement, calibration, configuration and diagnostics
  • Convenient turn-key AquaTrace DO monitoring system for reliable low DO measurements with a small footprint

Markets/Applications:

  • Process water, production and distribution: Collect quality control data
  • Food and beverage: Monitor process water quality
  • Pure water analysis: Accurate trace DO measurements and minimal drift

DataStick:

  • Provides universal conversion of sensor signals and interactive communications for measurement, calibration, configuration and diagnostics

Communications Adapter:

  • Plugs into the DataStick to provide power and direct interactive communications with control systems

AV38 Local Display:

  • Two-line display and seven-key navigation
  • Data reporting with up to two current outputs
  • Two Form C relays
  • Digital communications
  • AquaTrace ppb DO System with Trace DO ppb DataStick and flow cell installed
  • Trace ppb Dissolved Oxygen Sensor Head Pre-calibrated for ppb level dissolved oxygen and temperature
  • Can be plugged into any DataStick to yield accurate 24-bit data

AquaTrace ppb DO System:

  • Trace DO ppb DataStick and flow cell installed
Trace ppb Dissolved Oxygen Sensor Head:
  • Precalibrated for ppb level dissolved oxygen and temperature
  • Can be plugged into any DataStick to yield accurate 24-bit data

AquaChlor™ Free Chlorine Sensor and Monitoring System

AV38 DataStick Local Monitor and Controller

Conveniently display sensor and temperature data with the Thermo Scientific™ AquaSensors™ AV38 Local Digital Monitor and Controller, which connects to any Thermo Scientific™ DataStick™ system via 1/4 DIN enclosure.


AV88 AnalogPlus™ Universal Analyzer

Conveniently display sensor and temperature data with the Thermo Scientific™ AquaSensors™ AV88 AnalogPlus™ Universal Analyzer, which connects to any Thermo Scientific™AnalogPlus™ system via 1/4 DIN enclosure.

Description

Conveniently display sensor and temperature data with the Thermo Scientific™ AquaSensors™ AV88 AnalogPlus™ Universal Analyzer, which connects to any Thermo Scientific™AnalogPlus™ system via 1/4 DIN enclosure.

 
For Use With (Equipment) Thermo Scientific™ AnalogPlus™ system
Type Universal Analyzer
Description AV88 AnalogPlus Universal Analyzer
Max. Relative Humidity 95%, non-condensing
Outputs Two isolated 4 to 20mA outputs assigned to parameter; PID function with pH and Conductivity; Loop power provided by AV88
Power Supply Input 10 to 30VDC or 90 to 240VAC; (optional) Power: 2W at 25°C
Temperature (Metric) Operating -20° to +65°C
Item Description AV88
Sensor Connections Support pH, ORP, Two-electrode Conductivity and Resistivity, Toroidal Conductivity, Dissolved Oxygen, Ozone, and Turbidity measurementy; 1 in. long personality module plugs into the AV88 for use with any AnalogPlus sensor with a PT1000 temperature element
Certifications/Compliance Meets CE requirements for heavy industrial use
Unit Size -

AnalogPlus™ Differential pH Sensor 1.0 Inch

Conduct a wide array of demanding industrial applications with Thermo Scientific™ AquaSensors™ AnalogPlus™ Differential pH Sensors. Sensors are available in a choice of materials for a wide range of applications.

  • Replaceable salt bridge to extend sensor life
  • Offered with NTC300 or PT1000 temperature elements
  • Electrode protection options
 
For Use With (Equipment) AV88 Universal Analyzer
P99 pH/ORP Analyzer
Type Differential pH sensor
Accuracy 0.1% of reading
Description Differential pH sensor - 1.0 in.
Max. Flow Rate 10 ft./sec.
Max. Pressure 100psig (at 95°C); 85psig (at 75°C)
Step Response Time 90% in 30 seconds
Temperature (English) Operating 23° to 203°F PEEK Sensor Head; 23° to 167°F CPVC Sensor Head
Temperature (Metric) Operating -5° to +95°C (PEEK Sensor Head)/-5° to +75°C (CPVC Sensor Head)
Unit Size -

AnalogPlus™ Differential pH Sensor 1.5 Inch

Conduct a wide array of demanding industrial applications with Thermo Scientific™ AquaSensors™ AnalogPlus™ Differential pH Sensors. Sensors are available in a choice of materials for a wide range of applications.

  • Replaceable salt bridge to extend sensor life
  • Offered with NTC300 or PT1000 temperature elements
  • Electrode protection options
 
For Use With (Equipment) AV88 Universal Analyzer
P99 pH/ORP Analyzer
Type Differential pH sensor
Accuracy 0.1% of reading
Description Differential pH sensor - 1.5 in.
Max. Flow Rate 10 ft./sec.
Max. Pressure 100psig (at 95°C); 85psig (at 75°C)
Step Response Time 90% in 30 seconds
Temperature (English) Operating 23° to 203°F PEEK Sensor Head; 23° to 167°F CPVC Sensor Head
Temperature (Metric) Operating -5° to +95°C (PEEK Sensor Head)/-5° to +75°C (CPVC Sensor Head)
Unit Size -

AnalogPlus™ Differential ORP Sensor 1.0 Inch

Thermo Scientific AquaSensors AnalogPlus series for challenging process applications.

AquaSensors AnalogPlus ORP 1.0 Sensor

  • 1 inch NPT mounting
  • Differential ORP sensor designed for continuous use in the most demanding industrial applications
  • Replaceable salt bridge extends sensor life
  • Offered with NTC300 or PT 1000 temperature element
  • Electrode protection options
  • Available in choice of materials for a wide range of applications

Markets/Applications

  • Wastewater treatment
  • Metal finishing
  • Bleaching pulp
  • Disinfection control
 
For Use With (Equipment) AV88 Universal Analyzer
P99 pH/ORP Analyzer
Type Differential ORP sensor
Accuracy 0.1% of reading
Description Differential ORP sensor - 1.0 in.
Max. Flow Rate 10 ft./sec.
Max. Pressure 100psig (at 95°C); 85psig (at 75°C)
Step Response Time 90% in 30 seconds
Temperature (English) Operating 23° to 203°F PEEK Sensor Head; 23° to 167°F CPVC Sensor Head
Temperature (Metric) Operating -5° to +95°C (PEEK Sensor Head)/-5° to +75°C (CPVC Sensor Head)
Unit Size -


Switch to Mobile Version