LELab Sdn Bhd
18, Jalan Sungai Burung U32/U,
Seksyen 32, Bukit Rimau,
40460 Shah Alam,
Selangor Darul Ehsan, Malaysia.
+603-5525 3833
+603-5525 3832

Thermo Scientific Orion

Orion™ 7070iX TRO Analyzer

Thermo Scientific™ Orion™ analyzers are designed to provide fast, accurate and reliable online TRO (Total Residual Oxidant) detection – optimized for discharge applications that requires critical monitoring of TRO. Kits contains everything needed to operate and maintain the Orion 7070iX TRO analyzer.

PRODUCT OVERVIEW 


  • The new Thermo Scientific™ Orion™ 7070iX TRO Analyzer is designed to provide continuous and online measurement of TRO to ensure process treatment optimization. When dechlorination efficiency is paramount, TRO monitoring is a critical measurement.
  • Process control is achieved by measuring TRO online to ensure accurate dosing to control biological growth at optimal operational cost of biocides and oxygen scavengers
  • Ion selective electrode (ISE) technology solves these issues with significantly improved detection limit and accuracy using the existing USEPA approved Orion 97-70 ISE method.
  • Fast, accurate and reliable online TRO (Total Residual Oxidant) detection – optimized for discharge applications that requires critical monitoring of TRO.
  • Continuous and online measurement of TRO to ensure process treatment optimization.
  • Strict regulatory discharge permits in many countries (U.S. and Canada for example) require that chlorine levels must be monitored online
  • Higher detection limit
  • Larger error at low ppb level
  • Ion selective electrode (ISE) technology solves drift due to discoloring reagent and poor performance in sea water and other waters with interfering ions issues with significantly improved detection limit and accuracy using the existing USEPA approved Orion 9770 ISE method.

Orion™ 1816DO Low-Level Dissolved Oxygen Analyzer

Continuously monitor oxygen across a wide variety of low and trace level ppb level applications with the Thermo Scientific™ Orion™ 1816DO Low-Level Dissolved Oxygen Analyzer. Offering highly accurate measurement performance with proven reliability, the 1816DO analyzer provides effective process control you can trust.

  • PTFE membrane caps for sensor refurbishment in minutes
  • Rugged and sensitive galvanic dissolved oxygen sensor with rapid response
  • Offers high performance results
  • Galvanic dissolved oxygen sensor with unique Guard Ring™ technology; capable of consuming oxygen and associated gases

Orion™ 2111LL Low Level Sodium Analyzer

Protect your turbine against destructive sodium levels, including trace amounts, with the reliable and easy to use Thermo Scientific™ Orion™ 2111LL Low Level Sodium Analyzer. Available in several configurations including the analyzer instrument only, or with a protective enclosure.

Back to top

Features:

  • Resistant to drift with Orion™ Ross™ UltraTM electrode technology
  • Reduces hazardous waste
  • Easy to read backlit display for measurement visibility from a distance
  • No moving parts with the pum-less passive diffusion reagent system
  • Rapid response to changes and ultra low level detection with proprietary flow cell

Ordering information:

  • All low level sodium monitors come with step-by-step instructions for quick installation and start-up.
  • Available in several configurations including the analyzer instrument only or with a protective enclosure.

Orion™ 2111XP Sodium Analyzer

Meet the demanding needs of high-purity water measurements and high-acid cation exchange applications with the Thermo Scientific™ Orion™ 2111XP Sodium Analyzer. This system offers unmatched reliability in analyzing critical sample streams throughout the power/steam generation and industrial water industry. It is an all-in-one system from one of the most trusted names in sodium monitoring.

  • Provides early warning detection of sodium
  • Features simple, step-by-step scrolling instruction
  • Offers measurements at a glance with visible backlit display
  • Limits calibration cycles with Orion sodium electrode technology
  • Minimizes of operator time and maintenance without use of complicated moving parts or pumps
  • Detects limit of 0.1ppb
  • Offers flexible application packages suited for continuous sodium monitoring in a wide variety of samples

Orion™ 8030cX Silica Analyzer

Confidently perform silica analysis with the Thermo Scientific™ Orion™ 8030cX Silica Analyzer. Designed to provide accurate, effortless water analysis, the Orion 8030cX specializes in online measurement of reactive silica. Powered by advanced colorimetric technology, the Orion 8030cX delivers premium precision, greater productivity and enhanced durability. Supporting ultrapure and process water applications, the Orion 8030cX conveniently delivers precise, reliable measurement you can depend on. Unleash the possibilities and conquer the freedom of fast, confident decision making.

Orion™ 8010cX Process Ammonia Analyzer

Thermo Scientific™ Orion™ 8010cX is designed to provide easy to use, accurate, reliable and low maintenance ammonia online monitoring solution.8010cX is based on standard salicylic acid method, method traceable and reagents low toxicity. Professional industrial design, user interface design, modularity design, software function design, anti-interference measurement process design and algorithm enabled 8010cX can be applied in various different applications, to meet regulatory compliance and process control requirements.

Orion 3106COD Analyzer

The new “chemical oxygen demand” analyzer can prove beneficial to plants that treat wastewater. The COD analyzer will be yet “another tool” for the engineers to monitor “water quality and prevent environmental contamination”. 
  
The “COD analysis” helps in detecting the “levels of organic pollutants in water”. If the pollutants are identified quite early in the life cycle of the treatment plants than it indicates that there is “an issue” with “the treatment process of wastewater”. The latest addition in the portfolio “Orion products” that cater to the industry of wastewater treatment section, is the “Thermo Scientific Orion 3106 COD analyzer”. 
  
The analyzer goes through a digestion process along with “colorimetric analysis” whereby it determines the “concentration of organic compounds that can affect water quality”. If the analysis detect a high level of COD then the further “disinfection process” will require to treat the same whereby introducing “additional hypochlorite dosing”. Consequently, the chloramines are formed and if it exceeds a certain level it can even turn carcinogenic. 
 
“By determining organic pollutants in surface water or wastewater, COD measurement can provide a useful indicator of water quality, something that is essential to the environmental monitoring industry. By adding this new COD analyzer to our portfolio of portable and benchtop Orion water analysis instruments, we aim to provide environmental chemists with a complete solution to liquid analysis and measurement.” 
  
The new analyzer of COD has been made to bring down “ongoing operating costs” as it requires “low maintenance and reagent consumption”. However, the control of the treatment process will remain in the hands on the users whereby it will be possible to “reduce disinfection costs”. Moreover, the “intuitive user interface” makes navigation a simple task besides enhancing the experience of the operator. 

Orion™ 2210AM Ammonia Analyzer

Thermo Scientific™ analyzers are designed to provide fast, accurate and reliable online ammonia detection – optimized for drinking water applications that requires critical monitoring of free ammonia. The new Thermo Scientific™ Orion™ 2210AM Ammonia Analyzer is designed to provide continuous and online measurement of free ammonia in drinking water to ensure process treatment optimization. When system efficiency is paramount, ammonia monitoring is a critical measurement. Ammonia levels above 0.1mg/L in water indicate a polluted water source which can lead to drastic environmental effects including marine life and when combined with phosphate will lead to algae blooms.

  • Low reagent consumption due to a highly optimized, state of the art design
  • Wide range of detection – 0.03 - 30mg/L provides a complete picture of ammonia treatment process
  • Large, easy-to-read display allows for easy viewing in all types of lighting conditions
  • Simple menu navigation – an easy-to-read and understand menu structure
  • Compact size capable of being panel- or wall-mounted
  • Intelligent Sample Awareness – intelligent algorithm that senses the sample to keep the analyzer in a ready state, while offline, for up to 30 days

Orion™ 2002SS and 2002CC Conductivity Cells

Get reliable, high performance conductivity measurements with the durable Thermo Scientific™ Orion™ 2002SS and 2002CC Conductivity Cells.

2002CC

  • The 2002SS 2-electrode conductivity cell is stainless steel with a cell constant of 0.1cm-1
  • Sensor features a low cell constant value and is designed to provide high accuracy in low conductivity, ultra pure water and pure water samples in a process environment
  • Built with 316 stainless steel, this high purity sensor provides months of accurate measurements with virutally no maintenance between calibrations

2002SS

  • The 2002CC 4-electrode conductivity cell is an epoxy body sensor with a cell constant of 0.475cm-1
  • Sensor is ideal for high and standard conuctivity samples across a variety of industrial applications
  • Four-electrode design compensates for electrode fouling, cable and connector resistance or polarization errors
  • The epoxy/graphite cell material is extremly durable and chemically resistant

Orion™ 2001SC High Purity ROSS pH Electrode

Take high purity pH measurements with the highest accuracy and precision using the Thermo Scientific™ Orion™ 2001SC ROSS Combination pH Electrode. Combining pH sensing and reference electrodes, 2001SC provides a fast response for online pH electrodes.
The Thermo Scientific Orion 2001SC ROSS Combination pH Electrode is designed to be used in Thermo Scientific™ Orion™ stainless steel flow cell, which holds and positions the electrode for optimal results. This combination electrode uses patented ROSS technology. It has a specially designed flow cell for low conductivity samples and eliminates junction potential problems associated with conventional electrodes.

Reference System:

  • Platinum silver chloride-free
  • Drift-free, with precision 0.02 pH
Recommended For:
  • Ultra pure water
  • Potable water
  • Aqueous solutions

Orion™ pHR Process ROSS™ Electrode

The ROSS™ reference system provides a drift-free measurement system with accurate results. 

Features:

  • Room for 1 in. NPT mounting
  • A replaceable salt bridge that extends sensor life
  • A PT1000 temperature element
  • Customizable cable lengths of 10 to 30′ (kits are available for customization)

Benefits:

  • Accurate, reproducible results
  • Double junction design to prevent contamination
  • Unparalleled pH response to extreme temperature changes

Recommended for:

  • Wastewater Treatment
  • Pharmaceutical
  • Process Water
  • Industrial Water
  • Drinking Water
  • Power Effluent
  • Food Processing

Orion™ 1803 Steam Sample Conditioner

Take high-pressure steam samples at the reduced temperature and pressure levels required by our online analyzers using the Thermo Scientific™ Orion™ 1803 Steam Sample Conditioner. Process steam is used in many industries; it is the analysis of this steam that has made Orion online analyzers so important in the power, paper, petrochemical and other industries.

  • Handles pressures of up to 20897KPa (3030psi)— average pressure of process steam is approximately 6896KPa (1000psi)
  • Reduces the temperature of the sample from 538°C (1000°F) to under 38°C (100°F)
  • Requires no electrical hook up, so it can be used in multiple countries regardless of the voltage requirements
  • Can also be used in hazardous locations (e.g. petrochem) without any danger of explosion
  • Has a mechanical temperature shut off valve which will trip if the temperature exceeds 40°C (104°F)
  • Avoids costly damage if cooler fails or the cooling water becomes too hot; valve diverts the hot sample away from online monitor

Switch to Mobile Version