LELab Sdn Bhd
18, Jalan Sungai Burung U32/U,
Seksyen 32, Bukit Rimau,
40460 Shah Alam,
Selangor Darul Ehsan, Malaysia.
+603-5525 3833
+603-5525 3832

Orion Versa Star Pro pH/ISE/Conductivity/RDO/Dissolved Oxygen Multiparameter Benchtop Meter

Previous 1 / 8 Next

Orion Versa Star Pro pH/ISE/Conductivity/RDO/Dissolved Oxygen Multiparameter Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro pH/ISE/Conductivity/RDO/Dissolved Oxygen Multiparameter Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro pH/ISE/Conductivity/RDO/Dissolved Oxygen Multiparameter Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro pH/ISE/Conductivity/RDO/Dissolved Oxygen Multiparameter Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro pH/ISE/Conductivity/RDO/Dissolved Oxygen Multiparameter Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro pH/ISE/Conductivity/RDO/Dissolved Oxygen Multiparameter Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro pH/ISE/Conductivity/RDO/Dissolved Oxygen Multiparameter Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro pH/ISE/Conductivity/RDO/Dissolved Oxygen Multiparameter Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products


Orion Versastar Meter Basic Use
Description Orion Versa Star Pro benchtop meter with pH/ISE/mV module, conductivity/TDS/salinity/resistivity module, RDO/DO module and stand
Includes Versa Star Pro meter, VSTAR-ISE pH/ISE module, VSTAR-CND conductivity module, VSTAR-RD RDO/DO module, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate
Range (pH) -2.000 to 20.000pH
Resolution (pH) 0.1, 0.01, 0.001pH
Accuracy (pH) ±0.002pH
Range (mV) ±2000.0mV
Range (Relative mV) ±2000.0mV
Range (ORP) ±2000.0mV
Resolution (mV) 0.1mV
Accuracy (mV) ±0.2 mV or ±0.05% of reading whichever is greater
Range (ISE) 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none
Resolution (ISE) 0.0001 minimum, 1 to 4 significant digits (user selectable)
Accuracy (ISE) ±0.2 mV or ±0.05% of reading whichever is greater
Advanced ISE Functions Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability, incremental techniques including single known addition and subtraction, double known addition and subtraction, single analyte addition and subtraction
Isopotential Point 7.000pH (adjustable), 1.000 ISE (adjustable)
Range (Conductivity) 0.001 μS/cm to 3000 mS/cm
Resolution (Conductivity) 0.001 μS minimum, auto ranging up to 4 significant digits
Accuracy (Conductivity) 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
Range (TDS) 0.001 to 200.0 ppm
Resolution (TDS) 0.001 ppm minimum, auto ranging up to 4 significant digits
Accuracy (TDS) 0.5% of reading ±1 digit
TDS Factor Range Linear (0.02 to 9.99)
Range (Salinity) 0.06 to 80.00 psu, 0.05 to 42.00 ppt
Resolution (Salinity) 0.01 psu or 0.01 ppt minimum, auto ranging
Accuracy (Salinity) 0.5% of reading ±1 digit
Salinity Measurement Modes Practical salinity (psu) or natural sea water (ppt)
Range (Resistivity) 2 ohm to 100.0 meg-ohm
Resolution (Resistivity) 1 ohm or 0.1 meg-ohm, auto ranging
Accuracy (Resistivity) 0.5% of reading ±1 digit
Cell Constant 0.001 to 199.9cm-1
Temperature Compensation Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
Temperature (Metric) Reference 5°, 10°, 15°, 20°, 25°C
Range (Polarographic DO) 0.00 to 90.00mg/L
Resolution (Polarographic DO) 0.01, 0.1mg/L
Accuracy (Polarographic DO) ±0.2 mg/L or ±2% of reading, whichever is greater
Range (RDO) 0.00 to 50.00mg/L
Resolution (RDO) 0.01, 0.1mg/L
Accuracy (RDO) ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L
Percent Saturation Range (Polarographic DO) 0.0 to 600.0% saturation
Percent Saturation Resolution (Polarographic DO) 0.1, 1% saturation
Percent Saturation Relative Accuracy (Polarographic DO) ±2 % saturation or ±2% of reading whichever is greater
Percent Saturation Range (RDO) 0.0 to 500.0% saturation
Percent Saturation Resolution (RDO) 0.1, 1% saturation
Percent Saturation Relative Accuracy (RDO) ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation
Barometric Pressure Correction 400 to 850mmHg, automatic using built-in barometer or manual entry
Pressure Range 400 to 850mmHg
Pressure Resolution 0.1mmHg
Accuracy (Barometer) ±6 mmHg
Salinity Factor 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity
Calibration pH with calibration editing option, ion concentration (ISE) with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option, dissolved oxygen and temperature
Calibration Points (pH) 1 to 6
Calibration Points (ISE) 1 to 6
Calibration Points 1 point relative mV (RmV) mode, 1 point ORP mode
Calibration Points (Conductivity) Up to 6
Calibration Modes Water-saturated air, air-saturated water, manual (Winkler titration), zero point
Range (Temperature) -5.0 to 105.0 °C, 22.0 to 221.0 °F
Resolution (Temperature) 0.1°C, 0.1°F
Accuracy (Temperature) ±0.1°C
Temperature Selection Manual or automatic with ATC temperature probe
Temperature Probe Calibration 1 point temperature offset calibration
Channels 4 - customizable with modules
Display Type Color graphic LCD with user-customizable options
Backlight Option Yes
Keypad Numeric with menu-specific function keys and dual purpose scroll/shortcut keys
Measurement Modes pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature; conductivity, TDS, salinity or resistivity with temperature; dissolved oxygen as % saturation or mg/L with temperature and barometric pressure
Stability Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Data Management Details Transfer single, range or all data points to printer or computer
Data Points 2000 with date and time stamp
Log Function Type Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
Memory Non-volatile memory preserves data log, calibration log and meter settings
Alarm Output Set point alarm, high/low limit alarm, calibration due alarm
Methods 10 per channel
Languages English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
Inputs BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
Outputs USB (2), RS232
Power Supply Universal AC adapter (included)
AC Adapter Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)
IP Rating IP-54
Certifications/Compliance CE, TUV 3-1, FCC Class A
Temperature (English) Operating 41° to 113°F (ambient)
Temperature (Metric) Operating 5 to 45°C (ambient)
Relative Humidity Range 5 to 85%, non-condensing
Dimensions (L x W x H) 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H
Weight (Metric) 1.2kg, modules add 0.2kg each
Weight (English) 2.5 lb., modules add 0.5 lb. each
Warranty 3 year meter and module warranty
Power Rating DC input: 9VDC, 1A
Unit Size Each