Orion Versa Star Pro RDO/Dissolved Oxygen Benchtop Meter

Previous 5 / 8 Next

Orion Versa Star Pro RDO/Dissolved Oxygen Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro RDO/Dissolved Oxygen Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro RDO/Dissolved Oxygen Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products Orion Versa Star Pro RDO/Dissolved Oxygen Benchtop Meter Versa Star Benchtop Meters Thermo Scientific Orion Laboratory & Environmental Products


Relative Humidity Range 5 to 85 %, non-condensing
Certifications/Compliance CE, TUV 3-1, FCC Class A
Weight (English) 2.5 lb., modules add 0.5 lb. each
Weight (Metric) 1.2kg, modules add 0.2kg each
Dimensions (L x W x H) 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H
IP Rating IP-54
Temperature (English) Operating 41° to 113°F (ambient)
Temperature (Metric) Operating 5° to 45° C (ambient)
Description Orion Versa Star Pro benchtop meter with RDO/DO module and stand
Includes Versa Star Pro meter, VSTAR-RD RDO/DO module, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate
Range (Polarographic DO) 0.00 to 90.00mg/L
Resolution (Polarographic DO) 0.01, 0.1mg/L
Accuracy (Polarographic DO) ±0.2mg/L or ±2% of reading, whichever is greater
Range (RDO) 0.00 to 50.00mg/L
Resolution (RDO) 0.01, 0.1mg/L
Accuracy (RDO) ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L
Percent Saturation Range (Polarographic DO) 0.0 to 600.0 % saturation
Percent Saturation Resolution (Polarographic DO) 0.1, 1 % saturation
Percent Saturation Relative Accuracy (Polarographic DO) ±2 % saturation or ±2% of reading whichever is greater
Percent Saturation Range (RDO) 0.0 to 500.0 % saturation
Percent Saturation Resolution (RDO) 0.1, 1 % saturation
Percent Saturation Relative Accuracy (RDO) ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation
Sensor Types RDO optical dissolved oxygen sensor or polarographic dissolved oxygen sensor
Barometric Pressure Correction 400 to 850mmHg, automatic using built-in barometer or manual entry
Pressure Range 400 to 850mmHg
Pressure Resolution 0.1mmHg
Accuracy (Barometer) ±6mmHg
Salinity Factor 0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity
Calibration Modes Water-saturated air, air-saturated water, manual (Winkler titration), zero point
Range (Temperature) -5.0° to 105.0° C, 22.0° to 221.0° F
Resolution (Temperature) 0.1°C, 0.1°F
Accuracy (Temperature) ±0.1°C
Temperature Selection Automatic with ATC temperature probe
Temperature Probe Calibration 1 point temperature offset calibration
Channels 4 - customizable with modules
Display Type Color graphic LCD with user-customizable options
Backlight Option Yes
Keypad Numeric with menu-specific function keys and dual purpose scroll/shortcut keys
Measurement Modes Dissolved oxygen as % saturation or mg/L with temperature and barometric pressure
Stability Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Data Management Details Transfer single, range or all data points to printer or computer
Data Points 2000 with date and time stamp
Log Function Type Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
Memory Non-volatile memory preserves data log, calibration log and meter settings
Alarm Output Set point alarm, high/low limit alarm, calibration due alarm
Methods 10 per channel
Languages English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
Inputs 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), two stirrer inputs (stirrer probe)
Outputs USB (2), RS232
Probe Type RDO optical dissolved oxygen probe, polarographic dissolved oxygen probe, stirrer probe (purchase separately)
Power Supply Universal AC adapter (included)
AC Adapter Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)
Warranty 3 year meter and module warranty
Power Rating DC input: 9VDC, 1A
Unit Size Each